Starter Duty Cycle times

Can anyone tell me what the Starter duty cycle times are for

777 RR trent 892:

777 Ge90-115:


Thanks
wilco77 is offline  
Reply
Old 21st March 2015 | 16:52
  #2 (permalink)  
 
Joined: Sep 2010
Posts: 1,339
Likes: 0
From: earth
-115b is 5 minutes on 10 off.
grounded27 is offline  
Reply
Old 22nd March 2015 | 05:02
  #3 (permalink)  
Thread Starter
 
Joined: Jan 2003
Posts: 78
Likes: 0
From: alaska
Thanks for the info. But where is this written down in any of the manuals?
wilco77 is offline  
Reply
Old 22nd March 2015 | 07:24
  #4 (permalink)  
25 Anniversary
 
Joined: Jun 1999
Posts: 2,997
Likes: 35
From: Oztrailia
Usually that sort of information is contained in the LIMITATIONS section.

Not hard for a qualified Pilot trained on type to find...
ACMS is offline  
Reply
Old 24th March 2015 | 14:28
  #5 (permalink)  
 
Joined: Jul 2007
Posts: 183
Likes: 0
From: Sandy Surroundings!
Definitely NOT in the Limitations section of the FCOM! Reason, its not important to know!
TwinJock is offline  
Reply
Old 24th March 2015 | 22:53
  #6 (permalink)  
 
Joined: Aug 2006
Posts: 638
Likes: 0
From: South
It is not in the limitations section. Starter cycle is usually controlled by the autostart system. The autostart will only do two attempts for the GE and the RR will try three attempts.

Will check the MM next time I am at work.

Last edited by c100driver; 24th March 2015 at 22:58. Reason: additional info
c100driver is offline  
Reply
Old 25th March 2015 | 01:03
  #7 (permalink)  
25 Anniversary
 
Joined: Jun 1999
Posts: 2,997
Likes: 35
From: Oztrailia
Certainly is in my current A330 FCOM limitations section and it was in my old 777 FCOM limitations section as well.

Perhaps operator specific but I doubt it.
ACMS is offline  
Reply
Old 25th March 2015 | 02:48
  #8 (permalink)  
 
Joined: Aug 2006
Posts: 638
Likes: 0
From: South
Apparently it was removed from the FCOM and QRH some years back; would make sense as if the auto start does not work then you have a maintenance issue requiring engineering support.

From the MM

GE90 5 min on, 10 min off, 5 min on. Then starter cooling for 10 min minimum.

RR 3 min on, N3 to 10%, 3 min on, N3 to 0, 1 min on ,N3 to 0, 30 min Off

Interestingly the MM calls them guidelines!
c100driver is offline  
Reply
Old 25th March 2015 | 03:09
  #9 (permalink)  
25 Anniversary
 
Joined: Jun 1999
Posts: 2,997
Likes: 35
From: Oztrailia
It's certainly in the A330 FCOM Limitations Power Plant section, I just checked.

I'll have to download the 777 FCOM and see.


Ok, seems you are correct, Boeing has removed the starter limitations in the 777 FCOM's.

They were the same as the A330 RR Trent limits which are still in the A330 FCOM:--

Two 3 min duty cycles and a consecutive 1 min cycle is permitted with run down to zero N3 between each cycle.

Starter maximum continuous operation is 5 min . ‐ Two 3 min duty cycles and a consecutive 1 min cycle is permitted with run down to zero N3 between each cycle.

After one continuous operation, or the three cycles wait 30 min to allow the starter to cool. ‐ No running engagement of the starter when the N3 is above 10 % on ground, or 30 % in flight.
ACMS is offline  
Reply
Old 25th March 2015 | 04:14
  #10 (permalink)  
 
Joined: Apr 2008
Posts: 331
Likes: 2
From: Denver,Co USA
What I never understood about starter limits was if you have a start problem and have the starter right at limits and call maintenance the first thing they do is try it again. They must have different limits than pilots.
Rick777 is offline  
Reply
Old 26th March 2015 | 17:08
  #11 (permalink)  
Thread Starter
 
Joined: Jan 2003
Posts: 78
Likes: 0
From: alaska
Thanks guys for the info. Cheers
wilco77 is offline  
Reply
Old 30th March 2015 | 11:16
  #12 (permalink)  
 
Joined: Jun 2007
Posts: 191
Likes: 0
From: UK
I believe in the EPM it says you can try 457 attempts OR until the starter melts IF you are at an outstation AND you on your own. IF after the starter has melted, I think you may consult your company MCC for further support !

Terry McCassey is offline  
Reply

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2026 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.