B787-8 APU

From Stockholm Arlanda Airport extranet:

"In conjunction with the introduction of its B787-8, British Airways has applied for an exemption to use an auxiliary power unit (APU) throughout the turnaround process as recommended by Boeing."

Link: AI-121-2013 Exemption for use of APU - Swedavia Extranet

Anybody who knows the reason/s why behind "...as recommended by Boeing..."?

(BA is using the B787 on one flight between LHR-ARN-LHR per day during 09AUG-21SEP13 as part of the introduction of the aircraft)
gfmb is offline  
Old 12th Aug 2013, 10:24
  #2 (permalink)  
 
Join Date: Apr 2013
Location: Manchester, UK
Age: 35
Posts: 14
Likes: 0
Received 0 Likes on 0 Posts
This is pure guesswork but I guess the extra time is used to assess APU performance and as an APU is effectively an engine the extra running time will allow a mechanical run in period to ensure long term efficiency.

Last edited by squarehole; 12th Aug 2013 at 10:26.
squarehole is offline  
Old 12th Aug 2013, 11:54
  #3 (permalink)  
 
Join Date: Aug 2005
Location: Albuquerque USA
Posts: 174
Received 0 Likes on 0 Posts
shaft bowing?

My guess is that this is a reference to shut-down/startup restrictions related to the shaft bowiing problem.
archae86 is offline  
Old 12th Aug 2013, 14:55
  #4 (permalink)  
 
Join Date: Dec 2006
Location: Florida and wherever my laptop is
Posts: 1,350
Likes: 0
Received 0 Likes on 0 Posts
Archae86
My guess is that this is a reference to shut-down/startup restrictions related to the shaft bowiing problem.
This may well be the case as the turn around time for a short 'shuttle' flight may be a lot less than for the expected routine flights of the 787; 45 - 60 minutes compared to 90 to 180 minutes.
Ian W is offline  
Old 12th Aug 2013, 15:20
  #5 (permalink)  
 
Join Date: Jan 2011
Location: Seattle
Posts: 715
Likes: 0
Received 3 Likes on 2 Posts
In the linked article I see a reference to an "environmental permit". Perhaps they are trying to minimize the airport's carbon footprint by encouraging the use of ground power.
EEngr is offline  
Old 12th Aug 2013, 16:10
  #6 (permalink)  
 
Join Date: Aug 2000
Location: EGGW
Posts: 2,112
Likes: 0
Received 0 Likes on 0 Posts
It might be to save on the requirement for the two GPUs that would be required for the turn round.
Positioning the extra GPU and the removal may impact the access around the aircraft for the short turn round also.
Keeping the APU running also eliminates the APU failing to start, which is required to start the engines.
If the APU fails to start, you will then have to find a third GPU quickly for engine start-up or you will end up with a delay, which BA does not want.
Mr @ Spotty M is offline  
Old 12th Aug 2013, 16:16
  #7 (permalink)  
 
Join Date: Sep 1998
Location: wherever
Age: 55
Posts: 1,616
Likes: 0
Received 0 Likes on 0 Posts
How many GPUs does that thing need???!!!
FE Hoppy is offline  
Old 12th Aug 2013, 20:30
  #8 (permalink)  
 
Join Date: Aug 2000
Location: EGGW
Posts: 2,112
Likes: 0
Received 0 Likes on 0 Posts
If you only have 90 KVA producing units, you will need three for engine starting.
Mr @ Spotty M is offline  
Old 13th Aug 2013, 18:15
  #9 (permalink)  
 
Join Date: Apr 2005
Location: Stockholm Sweden
Age: 74
Posts: 569
Likes: 0
Received 0 Likes on 0 Posts
My guess is that this is a reference to shut-down/startup restrictions related to the shaft bowiing problem.
Correct. The BA780/! has a 1hr 15min gate stop. The rules with the APU cooling cycles don't leave any leeway if you shut it down.
Over on T5 (at ARN) we shut down the Qatar B787 APU, but that has around 2 hrs gate time and it works OK.
B787 must have two 90KVA GPU at the fwd connections at all times, or you get load shedding. It says in the book that you can start one engine with two GPUs, but we haven't tried yet. The APU easily starts both at once.
Swedish Steve is offline  
Old 14th Aug 2013, 12:39
  #10 (permalink)  
 
Join Date: Feb 2002
Location: UK
Age: 58
Posts: 3,500
Received 165 Likes on 89 Posts
In addition to the above, Ground power has a tendancy to drop off line under heavy loads. At the moment, an unexpected and non normal shutdown of the 787 computer systems will cause hours of resets and tests before dispatch.
Also, if you want air conditioning on ground, and there is no conditioned air available on stand, then either a 3rd GPU is required or run the APU.


Posted from Pprune.org App for Android
TURIN is offline  
Old 14th Aug 2013, 22:44
  #11 (permalink)  
 
Join Date: Jan 2008
Location: It used to be an island...
Posts: 244
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by TURIN
In addition to the above, Ground power has a tendancy to drop off line under heavy loads. At the moment, an unexpected and non normal shutdown of the 787 computer systems will cause hours of resets and tests before dispatch.
Also, if you want air conditioning on ground, and there is no conditioned air available on stand, then either a 3rd GPU is required or run the APU.
With the carbon bootprint (and non-CO2 emissions like soot and nitrous oxides) from (perhaps) three diesel GPUs grumbling away next to the aircraft, perhaps running a nice new clean turbine APU is looking like a better idea!

(Some of the ground power might come from fixed installations powered from the building mains but how many stands have 3 of those available, or even two - and how much dirtier is a diesel GPU than a Jet A1 APU?)
nicolai is offline  
Old 15th Aug 2013, 09:35
  #12 (permalink)  
 
Join Date: Apr 2005
Location: Stockholm Sweden
Age: 74
Posts: 569
Likes: 0
Received 0 Likes on 0 Posts
Here in Scandinavia, and most of Europe, running the APU on the ground is not an option. That is why we got the dispensation in the first place. On every other aircraft at ARN, the APU is shut down as soon as ground power is attached, and started again when the door is shut for departure.
Every gate has one FEGP, and they are very reliable, and nearly all the widebody gates here have two FEGP. It is not a good idea to run the packs from ground power, other systems will load shed, so the third GPU will only be required for an engine start. If it comes to it we will attempt a start from the two FEGP first and see how it goes. The AMM says it will work.

You can only use modern diesel GPUs on the B787, older ones do not have stable enough frequency. Modern GPUs are very quiet, and much preferable to an APU.
Get out on the ramp at ARN one day. Sometimes you can hear the birds singing it is so quiet!
Swedish Steve is offline  
Old 15th Aug 2013, 09:57
  #13 (permalink)  
 
Join Date: Jan 2008
Location: It used to be an island...
Posts: 244
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by Swedish Steve
Get out on the ramp at ARN one day. Sometimes you can hear the birds singing it is so quiet!
Sounds very pleasant! Thanks for the info.
nicolai is offline  
Old 15th Aug 2013, 23:21
  #14 (permalink)  
 
Join Date: Nov 2000
Location: Grobelling through the murk to the sunshine above.
Age: 60
Posts: 562
Likes: 0
Received 0 Likes on 0 Posts
The 787 APU is extremely quiet, and in fact is drowned-out by the CACs & Packs running when on the ground. Two GPUs would probably produce as much noise.
Pub User is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.