The B744/P&W Autostart procedure does not require running a clock. It is necessary for the EGT to rise by 20 seconds of fuel on, and for the idle rpm to be reached by 2 minutes. I have always assumed that the Autostart, by providing protection against Hung Start, Wet Start and Hot Start, will ensure the limitations are met, and the EEC has access to the ship's clock.
I was recently criticised by an IP for not running the clock, and was unable to prove my point that it is not necessary. His opinion was that the EEC might have its own schedule.
Does anyone have any information that would support/correct my assumptions?
 
Old 19th Nov 2000, 13:26
  #2 (permalink)  
Feather #3
Guest
 
Posts: n/a
Lightbulb

If I guess correctly, your Ops Manual will show the timing stuff under "Manual Start" as a Supplementary Normal.

"Normal Start" in the main body of 'Normal Procedures' will only refer to the use of 'Autostart'. No timimg mentioned.

You'll get into a similar argument with starter limitations!

Good luck!!!!

G'day
 

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.