A320 To APU or not to be, that is the emergency electrical question

Wikiposts
Search
Tech Log The very best in practical technical discussion on the web

A320 To APU or not to be, that is the emergency electrical question

Thread Tools
 
Search this Thread
 
Old 17th Dec 2023, 11:03
  #1 (permalink)  
Thread Starter
 
Join Date: Jul 2021
Location: Planet Earth
Posts: 36
Likes: 0
Received 0 Likes on 0 Posts
A320 To APU or not to be, that is the emergency electrical question

What criteria would you use to start the APU in a A320 emergency electrical configuration? Considering the feasibility.

and which phase?

As the probability of coupling is low. Any APU start will drain batteries.

Cheers


of course if you can start it better

right, there are pertinent differences in the newer versus older A320s

Last edited by Manual Pitch Trim; 17th Dec 2023 at 11:18.
Manual Pitch Trim is offline  
Old 17th Dec 2023, 12:32
  #2 (permalink)  
 
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,407
Likes: 0
Received 0 Likes on 0 Posts
If it's loss generators then only APU will connect. If it's faulty AC buses then APU won't connect. Still one attempt can be made
vilas is offline  
Old 17th Dec 2023, 20:20
  #3 (permalink)  
 
Join Date: Dec 2012
Location: NZ
Posts: 54
Received 1 Like on 1 Post
The QRH / ECAM instructs you to start the APU.

What criteria would you use to NOT start the APU?
waterbottle is offline  
Old 18th Dec 2023, 15:33
  #4 (permalink)  
 
Join Date: Jan 2022
Location: Miami
Posts: 93
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by Manual Pitch Trim
What criteria would you use to start the APU in a A320 emergency electrical configuration? Considering the feasibility.

and which phase?

As the probability of coupling is low. Any APU start will drain batteries.

Cheers


of course if you can start it better

right, there are pertinent differences in the newer versus older A320s
My opinion

- In any "non normal" electrical situation, making an attempt to start the APU is never a bad thing.

- Always follow ECAM, QRH procedure







321XLR is offline  
Old 19th Dec 2023, 11:02
  #5 (permalink)  
 
Join Date: Dec 1999
Location: In my own little world
Posts: 1,476
Likes: 0
Received 8 Likes on 2 Posts
Look at the generator output figures. If showing Freq and Volts they are working so the problem is downstream so unlikely the APU will connect. If showing zero and you have tried the reset they are the problem so probably worth trying a start and connection.

Not so sure about the

- Always follow ECAM, QRH procedure

What if you have a multiple birdstrike on T.O. and Eng 1 fails and Eng 2 bursts into flames but still runs. Going to follow ECAM then?
lurkio is offline  
Old 19th Dec 2023, 11:56
  #6 (permalink)  
 
Join Date: May 2009
Location: somewhere in the middle
Posts: 338
Likes: 0
Received 1 Like on 1 Post
Genuine question, has any A320 ever found itself in Emergency Electric?

I know we train for it, and it's good to think "what if", but really what are the chances?
thetimesreader84 is offline  
Old 19th Dec 2023, 13:03
  #7 (permalink)  
 
Join Date: Feb 2007
Location: Planet Earth
Posts: 113
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by thetimesreader84
Genuine question, has any A320 ever found itself in Emergency Electric?

I know we train for it, and it's good to think "what if", but really what are the chances?
https://avherald.com/h?article=50d67ba0&opt=0

Just a few months ago
PA38-Pilot is offline  
Old 19th Dec 2023, 16:35
  #8 (permalink)  
 
Join Date: May 2009
Location: somewhere in the middle
Posts: 338
Likes: 0
Received 1 Like on 1 Post
Originally Posted by PA38-Pilot
Wow, busy day out for those guys.

When I did my Type course 7/8 years ago, the instructor said there had never been an Emergency Elec Config that wasn't either planned (as part of an air test) or self inflicted (due wrong button pressing). Guess he was wrong.
thetimesreader84 is offline  
Old 26th Dec 2023, 23:16
  #9 (permalink)  
 
Join Date: Mar 2006
Location: Western Europe
Posts: 300
Received 2 Likes on 2 Posts
APU starting is inhibited for 40s after emergency electrical configuration entry. Reason most likely to get RAT on line as it's more important. Very nice if you then get the APU going.
Consol is online now  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.