Old 15th Aug 2012, 12:29
  #1 (permalink)  
Thread Starter
 
Join Date: Jul 2007
Location: USA
Posts: 372
Likes: 0
Received 0 Likes on 0 Posts
B744 HST Fuel pump operation

When departing with max fuel on the B744 (fitted with HST) is it the norm to already have the L and R STAB pump switches on before departure?

I am aware that the pumps won't actually run until the logic commands the feed to the CWT (CWT fuel approx. < 37,000Kgs).

So to sum it up, do you put them on from the start until the HST transfer begins automatically and is complete, or do you wait for the EICAS advisory to turn hem on so that transfer to the CWT can begin?

Last edited by B-HKD; 15th Aug 2012 at 12:36.
B-HKD is offline  
Old 15th Aug 2012, 13:09
  #2 (permalink)  
 
Join Date: Mar 2005
Location: UK
Posts: 134
Likes: 0
Received 0 Likes on 0 Posts
UK operator: turn them on and off according to EICAS
bylgw is offline  
Old 15th Aug 2012, 19:07
  #3 (permalink)  
Thread Starter
 
Join Date: Jul 2007
Location: USA
Posts: 372
Likes: 0
Received 0 Likes on 0 Posts
I suspect that only turning on the pumps when prompted to by the EICAS is a procedure that has been in place from the beginning on the 744.

Anyone know why they arent just put on (armed) like all other MAIN tanks before start?
B-HKD is offline  
Old 15th Aug 2012, 19:13
  #4 (permalink)  
 
Join Date: Nov 2007
Location: Texas
Posts: 1,921
Likes: 0
Received 1 Like on 1 Post
We wait for the EICAS message during climb. We'll get an EICAS message on the ground if the HST pumps are on according to the FCOM.
MarkerInbound is offline  
Old 15th Aug 2012, 21:16
  #5 (permalink)  
Thread Starter
 
Join Date: Jul 2007
Location: USA
Posts: 372
Likes: 0
Received 0 Likes on 0 Posts
Thanks MarkerInbound.

I found the >FUEL PMP STB L and >FUEL PUMP STB R EICAS advisories in the FCOM I have, as you mentioned. Makes perfect sense now why they are not armed on the ground.

I do wonder why the advisory was implemented in the first place for a fueled HST with pumps ON (ARMED) on the ground. Would make sense to have it set up properly before departure and just wait for the logic to activate the pumps.
B-HKD is offline  
Old 16th Aug 2012, 10:25
  #6 (permalink)  
 
Join Date: Jun 2001
Location: OZ
Posts: 1,129
Received 12 Likes on 6 Posts
That's how it was some years ago - turn the HST pumps on pre start and turn them off when the EICAS said so. Remember the pump overheat incidents? That changed Boeing thinking to more closely control the pumps to ensure they were never run dry, hence the current proceedure.
mustafagander is online now  
Old 16th Aug 2012, 18:54
  #7 (permalink)  
Thread Starter
 
Join Date: Jul 2007
Location: USA
Posts: 372
Likes: 0
Received 0 Likes on 0 Posts
That obviously explains the change in procedure. Thanks mustafagander.

I did some reading on the auto-shutoff SB etc. I know not all aircraft had it implemented, but there was a slight change in the EICAS advisory logic and the >FUEL PMP STAB L/R message as the FCOM shows (One of the FCOM's I have covers both pre SB and implemented SB)

Last edited by B-HKD; 16th Aug 2012 at 18:54.
B-HKD is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.