225 amps current limiter

Perhaps someone can help me understand how current limiter works.
On CJ there is a 225amps current limiter in crossfeed bus. According to training manual on the ground generator limit is 250 apms. So here is my question: When on the ground and one engine is running while crossfeeding power to all buses my limit is 225 amps and when both engines are running my amps limit now is 250 amps. Is that correct ?

Im asking because when we start one engine after lets say one week of no flying often gen amps is as high as lets say 220 amps. In such case I should wait till gen amps decrease below 200 before swithing on avionics in order not to exceed 225 amps of current limiter, correct ?
Dariuszw is offline  
Old 20th Apr 2012, 12:37
  #2 (permalink)  
 
Join Date: Apr 2004
Location: near EDDF
Posts: 775
Likes: 0
Received 0 Likes on 0 Posts
Im asking because when we start one engine after lets say one week of no flying often gen amps is as high as lets say 220 amps.
Dariuszw, Age: 17
IFixPlanes is offline  
Old 20th Apr 2012, 14:49
  #3 (permalink)  
 
Join Date: Apr 2010
Location: Home soon
Posts: 0
Likes: 0
Received 0 Likes on 0 Posts
Dariuszw, Age: 17
...with a mental age:6
de facto is offline  
Old 20th Apr 2012, 16:25
  #4 (permalink)  

Dog Tired
 
Join Date: Oct 2001
Location: uk
Posts: 1,688
Likes: 0
Received 1 Like on 1 Post
Oh, come on, it's just a question.

I have not flown the CJ but it sounds as if it's just a fuse (same in KingAir).

Yes, start first eng then allow the batteries to recover before starting second. Otherwise, the starting current reqd for the second eng start is likely to blow the fuse (current limiter).
fantom is offline  
Old 20th Apr 2012, 20:04
  #5 (permalink)  
 
Join Date: Sep 2007
Location: Down south
Posts: 670
Received 0 Likes on 0 Posts
If he knew the correct starting procedure for the CJ he would not need to ask the question, I believe the answer is in the checklist!
bingofuel is offline  
Old 21st Apr 2012, 04:55
  #6 (permalink)  
Thread Starter
 
Join Date: Dec 2011
Location: Paris, London and New York
Age: 29
Posts: 52
Likes: 0
Received 0 Likes on 0 Posts
Let me explain my problem in different way.

Current limiter in crossfeed bus is only 225 amps, yet allowable generator load in flight with single engine is 300 amps. How can 300 amps gen load be acceptable when crossfeed limiter is only 225 ?

Electrics was never my strong domains so having said that I assume that 300 amps load is being divided as it feeds three seperate busses and perhaps thats why 225 amps crossfeed limiter would not pop. Nevertheless I hope my older, wiser coligues can shed some light on it.
Dariuszw is offline  
Old 21st Apr 2012, 15:59
  #7 (permalink)  
 
Join Date: Dec 1998
Location: Escapee from Ultima Thule
Posts: 4,273
Received 2 Likes on 2 Posts
Because the single engine, 300A allowable load is supplying both its bus and, through the bus-tie, the bus for the failed generator. The working generator has to have a greater allowable load than the bus-tie in order to supply the bus-tie's load *plus* its own bus' load.

Last edited by Tinstaafl; 21st Apr 2012 at 17:40.
Tinstaafl is offline  
Old 21st Apr 2012, 16:09
  #8 (permalink)  
 
Join Date: May 2001
Posts: 10,815
Likes: 0
Received 0 Likes on 0 Posts
The limiter is there so that if the reason for the first generator going US was because of a short taking it out with over 300amps pulled.

Then when the bus tie is engaged it doesn't weld/crew keep there finger on it, it doesn't take the other one with it as well.
mad_jock is offline  
Old 22nd Apr 2012, 23:37
  #9 (permalink)  
 
Join Date: Jun 2010
Location: Canada
Age: 37
Posts: 382
Likes: 0
Received 0 Likes on 0 Posts
It would probably help to understand what current limiting actually is. You won't fully understand why it's 225 amps until you understand what a current limiter does and why they're in airplanes.

Current limiting - Wikipedia, the free encyclopedia
italia458 is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.