Hi all, just a quick question for reference. Is it possible to maintain the baggage hold temperature between 0-8c during flt (specifically on the VA 747-400's). As I'm not an engineer a straight yes or no will do for me, thanks.
Join Date: Jun 2005
Location: 20000 leagues under the sea
Posts: 147
Likes: 0
Received 0 Likes
on
0 Posts
AMM "A thermal barrier allows for independent selection for the aft containerized area and bulk area. Two selector switches each labeled CARGO HEAT are located in the aft and bulk cargo door areas to provide for 65F (20C) or 45F (5C) selection. "
Join Date: May 2000
Location: Seattle
Posts: 3,196
Likes: 0
Received 0 Likes
on
0 Posts
744 Freighters have selectors to control temp individually in the forward and aft lower cargo bays from 4-29C. The pax versions do not have that control on the flight deck.
Join Date: Feb 2004
Location: Australia
Posts: 1,307
Likes: 0
Received 0 Likes
on
0 Posts
Thermal switches normally control the temperature range. However, on freighters and, optionally, pax/combi aircraft, the cargo areas can be treated as an extension of the cabin air-conditioning system with variable temperature control.
Optional temperature ranges for the carriage of live animals (e.g. pets) are switchable on the more basic systems.
Are you questioning the ability of these systems to maintain the temperature range, or are you coming from a different angle?
Regards
NSEU
Optional temperature ranges for the carriage of live animals (e.g. pets) are switchable on the more basic systems.
Are you questioning the ability of these systems to maintain the temperature range, or are you coming from a different angle?
Regards
NSEU
Thread Starter
Join Date: Oct 2004
Location: East Sussex
Posts: 23
Likes: 0
Received 0 Likes
on
0 Posts
Thanks for the info so far. Just to clarify, I work for a catering company and we had an issue with a catering pod that malfunctioned (they have their own inbuilt cooling system) causing the return sector catering to spoil. So hence my question that is it possible for the hold temperature to be maintained between 0 - 8c which is the acceptable range for the perishable food. If this is possible then it could save ourselves and the airline possible future delays and money whilst down route catering is sourced with all its associated costs. The information I require is specific to the VA 747-400's.
Join Date: Feb 2004
Location: Australia
Posts: 1,307
Likes: 0
Received 0 Likes
on
0 Posts
Normally, the temperature in the lower cargo areas cannot be kept cold if the outside air temperature is higher than 8C. There is no refrigeration system, other than outside air temperature. On the ground, with the cargo doors open, the cargo temperature will be roughly the same as ambient.
What was the temperature at the departure and arrival airports on the day/s in question?
What was the temperature at the departure and arrival airports on the day/s in question?
Join Date: Feb 2004
Location: Australia
Posts: 1,307
Likes: 0
Received 0 Likes
on
0 Posts
Just to clarify, the standard cargo heat system can only *add* heat to ambient temperature. It can't subtract heat. Therefore, the airplane must be operating in temperatures at or below your specified maximum temp to guarantee the perishables remain within your defined temperature range.
Hope this makes sense
Rgds
NSEU
Hope this makes sense
Rgds
NSEU
Thread Starter
Join Date: Oct 2004
Location: East Sussex
Posts: 23
Likes: 0
Received 0 Likes
on
0 Posts
Thanks for the info NSEU, from what you have said my idea would not work as the a/c would need to maintain a hold temp of less than 8c for the duration of the flt and this could not be guaranteed so therefore the chance could not be taken. Thanks for your help and we'll have to hope the pod doesn't malfunction again.