hi...

i would like to know why the engine must be running and above idle power to diconnect the IDG.

and why the push button should not be held for more than 3 sec's (if my memory servs me right)

thanks
higher320 is offline  
Reply
Old 10th May 2008 | 07:57
  #2 (permalink)  
 
Joined: May 2005
Posts: 23
Likes: 0
From: AUS
IDG disconnect

A320.(for example )
When engine is not running, the IDG disconnect control signal is inhibited by the engine oil low pressure switch.

This prevents damage to the IDG disconnect mechanism. Mechanism includes:
solenoid, spring loaded disconnect plunger with threaded pawl, worm shaft and ground reset handle.

3 seconds maximum for IDG pushbutton to prevent damage to the disconnect solenoid.
N.E.R.D. is offline  
Reply
Old 10th May 2008 | 13:13
  #3 (permalink)  
20 Anniversary
 
Joined: Apr 2004
Posts: 775
Likes: 2
From: near EDDF
Originally Posted by higher320
i would like to know why the engine must be running and above idle power to diconnect the IDG.
If the input speed is too low, the centrifugal force cannot open the clutch
completely, this can lead to a clutch damage, such as broken teeth.

Originally Posted by N.E.R.D.
...Mechanism includes:
solenoid, spring loaded disconnect plunger with threaded pawl, worm shaft and ground reset handle.
Maybe this makes it clear:
IFixPlanes is offline  
Reply
Old 10th May 2008 | 20:29
  #4 (permalink)  
 
Joined: Mar 1999
Posts: 220
Likes: 0
From: KDEN
That diagram is very enlightening. What prevents the clutch from reengaging once the plunger releases?
Cardinal is offline  
Reply
Old 10th May 2008 | 21:14
  #5 (permalink)  
 
Joined: Sep 1998
Posts: 1,615
Likes: 1
From: wherever
the plunger is spring loaded. once triggered it remains in position until reset by pulling the loop on the end.

nice pic by the way!!
FE Hoppy is offline  
Reply
Old 11th May 2008 | 11:15
  #6 (permalink)  
 
Joined: Jan 2002
Posts: 960
Likes: 0
From: Brisbane, Australia
Sorry.....Errr.."clutch"....

My understanding, both before and after that great graphic, is that the spring-loaded plunger is released by the solenoid (when the DISC switch is held), and positions itself in the rotating wormdrive of the IDG input shaft.

That rotation then forces the wormdrive to displace the input shaft of the IDG such that the spline is fully withdrawn and all IDG rotation ceases, with (manual) reset only available on the ground with the engine shut down.

If the engine is operating at less than idle RPM, the spline drive may not fully withdraw, and although the IDG will still cease to rotate, the two will not be 100% disconnected, like just enough to damage the spline entry surfaces.

Understand, this is quite a violent mechanical action when actuated, the pin drops in and WHAM, the drive is forced out at great speed, enough to fully separate the two drive ends.

That's about as basic as I can explain it!

Cheers..FD..
Flight Detent is offline  
Reply

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Thread Tools
Search this Thread

Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2026 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.