A320.(for example )
When engine is not running, the IDG disconnect control signal is inhibited by the engine oil low pressure switch.
This prevents damage to the IDG disconnect mechanism. Mechanism includes:
solenoid, spring loaded disconnect plunger with threaded pawl, worm shaft and ground reset handle.
3 seconds maximum for IDG pushbutton to prevent damage to the disconnect solenoid.