APU Start during refueling
Thread Starter

Joined: Dec 2004
Posts: 75
Likes: 0
From: E&E compartment
APU Start during refueling
I can remember i saw in on the FCTM on of the updates fore 2004 that the restriction not to start APU during refueling was deleted. I lost that update and i can't find something to prove that APU can be started while refueling is going on.
Anyone has that update on PDF ?
Thanks,
Anyone has that update on PDF ?
Thanks,
Joined: Mar 2000
Posts: 1,337
Likes: 1
From: Sunrise Senior Living
From FCOM 2.01.30 P10a
"APU starts or shutdowns are permitted during refuel/defuel procedures. If it is necessary to operate the APU, the limits that follow apply :
An APU start is not permitted during a refuel/defuel procedure if the APU has failed to start or an automatic shutdown has occured
A normal APU shutdown must be completed if a fuel spill has occured during the refuel defuel procedure."
That's all very well, but the fuel companies have their own rules. It is good manners to ask the refueller whether he minds or not.
Cheers,
mcdhu
"APU starts or shutdowns are permitted during refuel/defuel procedures. If it is necessary to operate the APU, the limits that follow apply :
An APU start is not permitted during a refuel/defuel procedure if the APU has failed to start or an automatic shutdown has occured
A normal APU shutdown must be completed if a fuel spill has occured during the refuel defuel procedure."
That's all very well, but the fuel companies have their own rules. It is good manners to ask the refueller whether he minds or not.
Cheers,
mcdhu
Joined: Jul 2000
Posts: 399
Likes: 0
From: West
It was deleted in 2005
Originally Posted by FMC OVERHEAT
I can remember i saw in on the FCTM on of the updates fore 2004 that the restriction not to start APU during refueling was deleted. I lost that update and i can't find something to prove that APU can be started while refueling is going on.
Anyone has that update on PDF ?
Thanks,
Anyone has that update on PDF ?