Wikiposts
Search

Notices
Engineers & Technicians In this day and age of increased CRM and safety awareness, a forum for the guys and girls who keep our a/c serviceable.

747 "Classic" Q?

Thread Tools
 
Search this Thread
 
Old 9th April 2005 | 12:37
  #1 (permalink)  
Thread Starter
 
Joined: Jul 2000
Posts: 1,424
Likes: 0
From: Smogsville
747 "Classic" Q?

Could someone tell me,

If the Equipment cooling, NO AIRFLOW light on P4 (F/E Panel) comes on, I believe it goes into SMOKE mode and the flight deck blower stops and the dump valve opens. Now does pushing the reset switch start the fan again or does it have to be held down (I suppose your on the ground and there is no diff P) so to run the fan until the NO AIRFLOW light goes out.

Any help greatly appreciated and you can expect more Qs.

Rgds SMOC
SMOC is offline  
Old 10th April 2005 | 09:53
  #2 (permalink)  
 
Joined: May 2004
Posts: 934
Likes: 0
From: Balmullo,Scotland
This situation usually occurs when no ground power is available and also co-incides with the equipment cooling horn sounding(very loudly)the only way the FE panel push button can be reset and subsequent cooling air being restored is to apply grnd power and hold the pushbutton till the warning light goes out and the horns stops.The flt deck blower and dump valve are unaffected in this situation.
MK
matkat is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2026 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.