GB: answer to your inquiry is in my post #44. For your conveniance I paste it again:
In normal flight however, with the battery switch on, stby pwr not in bat position, K2 is closed and connects TR3 to the bat bus via SPCU.
K2 is the normal batt bus relay switch.
I have trouble understanding what makes this so difficult to comprehend.