IO540 (in a TB20)
Throttle 1/4", mixture rich, prime with fuel pump
6 seconds if cold
2 seconds if warm (doesn't start? Prime again 2secs)
0 seconds if hot (doesn't start? Prime 2secs)
Fuel pump off, mixture cut-off, engage starter and mixture back to rich when it fires. Works everytime for me.