Hi TyroPicard,
NO ! We are in selected speed.......
I agree that we use selected speed to decelerate to VFE next-5.

However, once in the landing config, and with the appropriate VAPP inserted into the MCDU, why can't we use managed speed to take advantage of ground speed mini protection?