@adarob:
You drive the IP (N2) compressor by opening the VIGV and then N2 first stage compressor blades can be accessed by sticking in a special tool (stick) between 2 fanblades and VIGV.
You will rotate the N2 'blade by blade'.
The handcrancking pad on youre picture drives only the N2!.