Lamidanda (LDN) Nepal?
Also, I am looking for information on the fire extinguishing systems for the -400 please
*There are two fire extinguisher bottles in each wing for the two engines on that wing, one or both bottles can be discharged in either engine on a wing.
*There is one APU fire extinguisher bottle controlled by the APU Fire switch.
*There are four fire extinguisher bottles for the forward and aft cargo
compartments. Pushing the Cargo Fire Discharge switch discharges two bottles immediately. The other two bottles discharge after a brief delay, or upon touchdown.
Are you looking anything more specific than that?