Not looked at my FCOMs but off the top of my head if the FADEC detects any of the reverser doors unlocked/deployed etc and reverse is NOT selected then it will automatically select idle power for the engine. Now if this happens between 100kts and V1 well then you to all intents and purpose an engine failure before V1 and so should stop?