747 Classic APU generator and JT9D-7 Series generators are the same and interchangeable. The JT9 used a CSD to maintain constant speed for generator output. The generator and CSD were mounted on opposite sides of the gearbox to each other. I also believe the GENX engine uses a starter/generator.