Stall Warning
Stall Warning is only inhibited on the ground. From FCOM 1.34.10:
An aural stall warning is triggered when the AOA
is greater than a predetermined angle.
This angle depends on the:
- Slats/Flaps position
- Speed/Mach
- F/CTL law (normal, alternate/direct)
In other words Vs will vary with F/CTL law - with (my guess) a higher value in alternate law. When we train low speed protections in normal law the stall warning does not sound - the protections prevent the a/c getting to that AOA.
Edited to correct stupid mistake!
Last edited by TyroPicard; 27th Feb 2009 at 12:18.