PPRuNe Forums - View Single Post - Dual Engine Flameout B777
View Single Post
Old 29th Oct 2006, 20:59
  #1 (permalink)  
purple
 
Join Date: Feb 2003
Location: Changmai
Posts: 15
Likes: 0
Received 0 Likes on 0 Posts
Dual Engine Flameout B777

Quick Question:
Dual Engine Flameout B777: Part of the Recall item; Fuel Control Switches to Cutout and then to Run.
When carrying out wind-milling start - After sometime, when the engines fail to start, do you knock the Fuel Control Switches to cutout and Run again?
It does not say anywhere in the checklist to carry this out again. Pls correct me if I am wrong.
As I understand it, once the recall item is done, this energises the start sequence and there is no need to to carry out that particular recall item again.
If that particular recall item is to be carried out again, when do you attempt it? Height? Time?
Any inputs? Many thanks.
purple is offline