My company allows you to continue a Cat IIIa approach with an autothrottle failure. PNF calls 25ft RA for throttles to be closed.
I had to do one for real several years ago after the autothrottle could not handle stiff thrust levers on the approach. I just closed them the way I had seen it happen on other autolands or in the sim and it worked fine.