A320 Center Tank Pumps
Hi All
Why does the A320 center tank pumps run for 5 mins after the center tank runs dry? Thanks |
Hi arrow28,
Technically the 5 mins timer doesn't start when the tank is "dry". It starts from when the CTR TK LO LVL sensor is triggered. (DSC-28-10-30 Engine Feed CENTER TANK PUMPS CONTROL LOGIC diagram.) There is still a small amount of fuel in the centre tank which can normally be scavenged out in 5 mins. |
GR
Would you happen to know at what levels the LO LVL sensors are triggered. |
Is this a question? :confused:
|
If that was a question, then this is an answer.
.... at what levels the LO LVL sensors are triggered. |
GR
Thank you. |