A320 Ventilation
ECAM procedure VENT BLOWER FAULT says if you have a DC ESS BUS FAULT along with VENT BLOWER FAULT , the crew should LAND ASAP. What has DC ESS BUS got to do with the Ventilation blower fan? As per FCOM the blower is powered by AC1 and DC1.
|
It might be something to do with the avionics air conditioning valve being inop with a DC ESS BUS fault combined with a blower fault. Not sure though.
|
looking at the schematic: DSC 21-30-20- ABN Operation:
BLOWER/EXTRACT FAULT ALERT When either pb is set at the OVRD position: The system is in closed-circuit configuration and adds air from the AIR CONDITIONING System to the ventilation air As mentioned by Mr BH; in conjunction with a DC ESS BUS FAULT, leading to the closure of the AIR COND INLET VALVE (Other inop systems), a computer over heat may develop. |
Thank you for your time. That solves my question.:)
|
Also with DC ESS bus fault , extract fan is inop.
|