A320 Ventilation
Thread Starter
Join Date: Oct 2011
Location: Mars
Posts: 7
Likes: 0
Received 0 Likes
on
0 Posts
A320 Ventilation
ECAM procedure VENT BLOWER FAULT says if you have a DC ESS BUS FAULT along with VENT BLOWER FAULT , the crew should LAND ASAP. What has DC ESS BUS got to do with the Ventilation blower fan? As per FCOM the blower is powered by AC1 and DC1.
Join Date: Feb 2015
Location: Middle East
Posts: 103
Likes: 0
Received 0 Likes
on
0 Posts
looking at the schematic: DSC 21-30-20- ABN Operation:
BLOWER/EXTRACT FAULT ALERT
When either pb is set at the OVRD position:
The system is in closed-circuit configuration and adds air from the AIR CONDITIONING System to the ventilation air
As mentioned by Mr BH; in conjunction with a DC ESS BUS FAULT, leading to the closure of the AIR COND INLET VALVE (Other inop systems), a computer over heat may develop.
BLOWER/EXTRACT FAULT ALERT
When either pb is set at the OVRD position:
The system is in closed-circuit configuration and adds air from the AIR CONDITIONING System to the ventilation air
As mentioned by Mr BH; in conjunction with a DC ESS BUS FAULT, leading to the closure of the AIR COND INLET VALVE (Other inop systems), a computer over heat may develop.
Last edited by Feather44; 23rd Nov 2015 at 22:52.