PPRuNe Forums

PPRuNe Forums (https://www.pprune.org/)
-   Tech Log (https://www.pprune.org/tech-log-15/)
-   -   shut down then restart of APU on 737 -800 (https://www.pprune.org/tech-log/324845-shut-down-then-restart-apu-737-800-a.html)

RISK AVERSE 29th Apr 2008 09:12

shut down then restart of APU on 737 -800
 
hi,

Heres the scenario,

Taxi onto stand, ground crew connect ground power, and subsequently connect aircraft to ground power. APU shut down. Ground power fails and disconnects. position APU switch back to ON, APU still in shutdown cycle, but AC still available and APU continues to run, and APU ON BUS now.

Is this healthy for the APU?

RiskAverse

TechCons 29th Apr 2008 12:44

I'm not sure if its different on the NG, but on the Classic this was a normal function. When you move the switch back to the 'run' position the shutdown mode is abandoned and the APU continues to run normally, with air and electrics available.

Engineer_aus 30th Apr 2008 12:31

Doesn't harm it at all.


All times are GMT. The time now is 11:45.