shut down then restart of APU on 737 -800

hi,

Heres the scenario,

Taxi onto stand, ground crew connect ground power, and subsequently connect aircraft to ground power. APU shut down. Ground power fails and disconnects. position APU switch back to ON, APU still in shutdown cycle, but AC still available and APU continues to run, and APU ON BUS now.

Is this healthy for the APU?

RiskAverse
RISK AVERSE is offline  
Old 29th Apr 2008, 12:44
  #2 (permalink)  
 
Join Date: Mar 2004
Location: UK
Age: 64
Posts: 36
Likes: 0
Received 0 Likes on 0 Posts
I'm not sure if its different on the NG, but on the Classic this was a normal function. When you move the switch back to the 'run' position the shutdown mode is abandoned and the APU continues to run normally, with air and electrics available.
TechCons is offline  
Old 30th Apr 2008, 12:31
  #3 (permalink)  
 
Join Date: Apr 2008
Location: Australia
Posts: 343
Likes: 0
Received 0 Likes on 0 Posts
Doesn't harm it at all.
Engineer_aus is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.