A320 G+B and RAT deployment

In a scenario of G+B dual hydraulic failure, assuming G system is lost due to low level and B system is lost either due to reservoir overheat or pump overheat, is deployment of RAT from HYD panel advisable? The FCOM checklist mentions " IF B SYS LOST BY ELEC PUMP LO PR: ......RAT MAN ON"....

My understanding is that the following cases will lead to B SYS LO PR
# In case of B electric pump overheat, the ECAM will instruct you to switch off B pump leading to system B system low pressure.
# B reservoir overheat also calls for B ELEC pump to be off and leads to B system low pressure.

Will following the ECAM and deploying the RAT aggravate the overheat condition?
Higgs boson is offline  
Old 21st Sep 2021, 16:35
  #2 (permalink)  
 
Join Date: Jan 2014
Location: N5109.2W10.5
Posts: 720
Likes: 0
Received 0 Likes on 0 Posts
“Will following the ECAM and deploying the RAT aggravate the overheat condition?”

No. From memory, I think the ECAM invitation to deploy the RAT only appears when Blue Reservoir overheat has extinguished. The original overheat was probably due to a problem with the Blue Electric pump.

Last edited by Goldenrivett; 23rd Sep 2021 at 14:24. Reason: Quote from Higgs boson added due having being deleted by ?
Goldenrivett is offline  
Old 21st Sep 2021, 16:39
  #3 (permalink)  
 
Join Date: Sep 2011
Location: FL390
Posts: 241
Likes: 0
Received 0 Likes on 0 Posts
Don't forget that there's a difference between B SYS LO PR and B ELEC PUMP LO PR.

The ECAM has the condition statement: "If blue sys lost by ELEC PUMP LO PR", so the line to deploy the RAT manually shouldn't appear. Not on the A320 any more but I remember that hydraulic ECAMs were fairly straightforward.

If I'm wrong please correct my understanding because it's been three years.


Edit: crossed with goldenrivet.
Fursty Ferret is online now  
Old 22nd Sep 2021, 04:47
  #4 (permalink)  
 
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,407
Likes: 0
Received 0 Likes on 0 Posts
There is RAT for Blue electric pump and PTU between G and Y EDPs and also electric pump for Yellow. The ECAM philosophy for the use of redundancy is same. They are only available if the main pump produces low pressure. They are to be switched off if the low pressure is due to reservoir low level and the system is lost. In case of reservoir overheat or reservoir air low pressure they are switched off till the condition disappears and then an attempt is suggested to recover the system.
The general logic is G and Y are main systems so their loss the system tries to recover, subject to conditions mentioned above automatically through PTU. In case PTU has a problem Yellow services are recovered through Yellow electric pump. Green having too many services is only recoverable through PTU. If not then services are lost. In case of single hydraulic B failure, since it doesn't have many services and the complications of unretractable RAT it's not recovered through RAT but taken as lost. Only in case of dual hydraulic failure ECAM tells you to recover the B through RAT. to bring it to single failure.

Last edited by vilas; 22nd Sep 2021 at 10:33.
vilas is offline  
Old 22nd Sep 2021, 12:15
  #5 (permalink)  
Thread Starter
 
Join Date: Sep 2021
Location: Area51
Posts: 22
Likes: 0
Received 0 Likes on 0 Posts
If its a G+B failure and B sys is lost due to reservoir overheat, will ECAM ask you to deploy RAT?
Higgs boson is offline  
Old 22nd Sep 2021, 12:39
  #6 (permalink)  
 
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,407
Likes: 0
Received 0 Likes on 0 Posts
The answer is No! ECAM will only ask you to switch off B electric pump.
During APP procedure it will ask you if blue overheat out then put B electric pump on, not the RAT.
vilas is offline  
Old 22nd Sep 2021, 15:26
  #7 (permalink)  
Thread Starter
 
Join Date: Sep 2021
Location: Area51
Posts: 22
Likes: 0
Received 0 Likes on 0 Posts
If I remember it correctly, switching off the B electric pump lead to B sys low pressure. This, coupled with the G HYD low level made the ECAM to display "RAT ON". My instructor had to specifically tell me not to deploy RAT because of the B reservoir overheat condition. Maybe its a simulator error. It felt odd not to follow the ECAM.
Higgs boson is offline  
Old 22nd Sep 2021, 17:03
  #8 (permalink)  
 
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,407
Likes: 0
Received 0 Likes on 0 Posts
You may be having blue electric pump overheat and not reservoir overheat. If problem is with B Electric pump it is replaceable by RAT but for single B fail it will only ask you to switch off electric pump and accept the loss of B system. But if Blue loss is second system loss or blue loss is the first loss followed by G or yellow loss then it will ask for Blue electric pump off and RAT on. I hope it's clear now.
vilas is offline  
Old 23rd Sep 2021, 16:47
  #9 (permalink)  
Thread Starter
 
Join Date: Sep 2021
Location: Area51
Posts: 22
Likes: 0
Received 0 Likes on 0 Posts
What I understand from the above is, in case of HYD G+B Lo PR(B lost due to elect pump overheat), B elect pump off....RAT ON.
In the case of HYD G+B lo PR(B lost due to reservoir overheat), B electric pump off....But NO RAT!
Higgs boson is offline  
Old 23rd Sep 2021, 17:39
  #10 (permalink)  
 
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,407
Likes: 0
Received 0 Likes on 0 Posts
Yes! That is correct.
vilas is offline  
Old 27th Sep 2021, 12:10
  #11 (permalink)  
 
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,407
Likes: 0
Received 0 Likes on 0 Posts
Higgs boson

And when B reservoir overheat out B electric pump Auto.
vilas is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.