What electrical source powers LGCIU1?
Thread Starter
Join Date: Jun 2014
Location: UK
Posts: 12
Likes: 0
Received 0 Likes
on
0 Posts
What electrical source powers LGCIU1?
A320.
I thought LGCIU1 was powered by the DC ESS BUS but the Abnormal and Emergency Procedures does not list LGCIU1 under the Inop Sys for a DC ESS BUS Fault. In the event of a DC BUS 2 fault you lose LGCIU2 and if you have both these faults at the same time a gravity gear extension is required, presumably because of the loss of both LGCIUs, implying the DC ESS is the source powering LGCIU1, I don’t imagine it being on the SHED. Can anyone confirm this, it’s a shame the old FCOM 1-4 used to list quite clearly and I don’t have a copy.
I thought LGCIU1 was powered by the DC ESS BUS but the Abnormal and Emergency Procedures does not list LGCIU1 under the Inop Sys for a DC ESS BUS Fault. In the event of a DC BUS 2 fault you lose LGCIU2 and if you have both these faults at the same time a gravity gear extension is required, presumably because of the loss of both LGCIUs, implying the DC ESS is the source powering LGCIU1, I don’t imagine it being on the SHED. Can anyone confirm this, it’s a shame the old FCOM 1-4 used to list quite clearly and I don’t have a copy.
Thread Starter
Join Date: Jun 2014
Location: UK
Posts: 12
Likes: 0
Received 0 Likes
on
0 Posts
Thanks,
I see the DC GND/FLT supply from TR2 but the list of loads that can be energized does not include LGCIU1. Do you have a reference I can follow up?
I see LGCIU1 is available in EMER ELEC so that seems logical that DC ESS Is powering it via ESS TR when TR2 is not available. I cannot find any description of this in the FCOM though. Very frustrating.
Can anyone post a list of kit powered by the DC FLT BUS, I’m interested to know how a DC FLT BUS Fault would present itself on ECAM because it sounds like a minefield to diagnose.
I see the DC GND/FLT supply from TR2 but the list of loads that can be energized does not include LGCIU1. Do you have a reference I can follow up?
I see LGCIU1 is available in EMER ELEC so that seems logical that DC ESS Is powering it via ESS TR when TR2 is not available. I cannot find any description of this in the FCOM though. Very frustrating.
Can anyone post a list of kit powered by the DC FLT BUS, I’m interested to know how a DC FLT BUS Fault would present itself on ECAM because it sounds like a minefield to diagnose.
Join Date: Mar 2003
Location: cheese- & chocolateland
Age: 57
Posts: 4
Likes: 0
Received 0 Likes
on
0 Posts
I'm not qualified anymore on the A320 and have no FCOM available.
We have a genius at our airline creating wonderful summaries. Maybe this graphic helps....
free download at pmgasser(dot)ch
We have a genius at our airline creating wonderful summaries. Maybe this graphic helps....
free download at pmgasser(dot)ch