Old 10th Oct 2019, 07:06
  #1 (permalink)  
Thread Starter
 
Join Date: Apr 2006
Location: Asia
Age: 49
Posts: 524
Likes: 0
Received 0 Likes on 0 Posts
A320 Auto Xbleed

Anyone knows why the Auto X Bleed logic is not included in the engine relight scenario?
MD83FO is offline  
Old 10th Oct 2019, 12:10
  #2 (permalink)  
 
Join Date: Apr 2010
Location: in the sky allways
Posts: 65
Likes: 0
Received 0 Likes on 0 Posts
Its already there in the NEO... just saw that in the neo sim...
speedbird787 is offline  
Old 11th Oct 2019, 12:40
  #3 (permalink)  
 
Join Date: May 2013
Location: Austria
Posts: 15
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by MD83FO
Anyone knows why the Auto X Bleed logic is not included in the engine relight scenario?
You have to manually turn the X-Bleed knob to OPEN.

It's not automatic ! Imagine ie. Eng FIRE or BMC1 fault ( A320 APU's bleed pipe is on the left pipe line side compared to X-Bleed Valve POS.)

Please follow QRH Procedure. Normally Windmill Quick relight works with airspeed 300kt.


PS. It's the same way when you perform X-bleed engine start on ground 1. APU bleed off (ensure engine bleed off) 2. Manually X-bleed OPEN.
noptawat is offline  
Old 11th Oct 2019, 12:43
  #4 (permalink)  
Thread Starter
 
Join Date: Apr 2006
Location: Asia
Age: 49
Posts: 524
Likes: 0
Received 0 Likes on 0 Posts
will this logic change when pilots are removed from the cockpit?
MD83FO is offline  
Old 12th Oct 2019, 11:24
  #5 (permalink)  
 
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,406
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by MD83FO
Anyone knows why the Auto X Bleed logic is not included in the engine relight scenario?
It is according to the logic only.The logic only opens the Xbleed automatically when APU BLEED is on otherwise it remains closed. When engine fails the XBleed remains closed.That's why if fire button is not pushed you get a ECAM "If performance permits X bleed open". Engine relight procedure wants to use Iive engine bleed if wind milling is less. Since the X bleed does not automatically open it asks you to open manually.

Last edited by vilas; 13th Oct 2019 at 06:00.
vilas is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts