A320 Auto Xbleed
Join Date: May 2013
Location: Austria
Posts: 15
Likes: 0
Received 0 Likes
on
0 Posts
It's not automatic ! Imagine ie. Eng FIRE or BMC1 fault ( A320 APU's bleed pipe is on the left pipe line side compared to X-Bleed Valve POS.)
Please follow QRH Procedure. Normally Windmill Quick relight works with airspeed 300kt.
PS. It's the same way when you perform X-bleed engine start on ground 1. APU bleed off (ensure engine bleed off) 2. Manually X-bleed OPEN.
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,406
Likes: 0
Received 0 Likes
on
0 Posts
It is according to the logic only.The logic only opens the Xbleed automatically when APU BLEED is on otherwise it remains closed. When engine fails the XBleed remains closed.That's why if fire button is not pushed you get a ECAM "If performance permits X bleed open". Engine relight procedure wants to use Iive engine bleed if wind milling is less. Since the X bleed does not automatically open it asks you to open manually.