Big planes have them, small planes don't. At what size does this become a necessity. What is the smallest aircraft type you know of with surge tanks?
Join Date: Jun 2014
Location: Mordor
Posts: 338
Likes: 0
Received 0 Likes
on
0 Posts
It’s not about size I think. More than I’ve seen fuel spilling through vents out of of a over fueled Cessna or some such...
I suspect surge tanks are required by CS25 specifications, that’s why big planes have them...
I suspect surge tanks are required by CS25 specifications, that’s why big planes have them...
Thread Starter
Join Date: Nov 2004
Location: Here, there, and everywhere
Posts: 1,125
Likes: 0
Received 13 Likes
on
8 Posts
Maybe someone could let us know if there is a regulatory requirement.
I would assume this be the regulatory requirement.
FAR 23 aircraft don't seem to have any explicit requirement. As SnR notes, you will see fuel coming from vents, usually after refuelling, the cold fuel expands under the influence of the sun on the wing warming. Have seen fuel venting in high wing Cessnas in flight in steep nose down conditions following refuelling.
§25.969 Fuel tank expansion space.Each fuel tank must have an expansion space of not less than 2 percent of the tank capacity. It must be impossible to fill the expansion space inadvertently with the airplane in the normal ground attitude. For pressure fueling systems, compliance with this section may be shown with the means provided to comply with §25.979(b)
Thread Starter
Join Date: Nov 2004
Location: Here, there, and everywhere
Posts: 1,125
Likes: 0
Received 13 Likes
on
8 Posts
Thanks,
So it looks like every FAR 25 aircraft is required to have surge tanks.
I see from the ATR-42 manual that they follow the regulation for 2%...."An additional volume in each tank allows a 2% thermal expansion of fuel without spillage."
It would be interesting to know if there are surge tanks on an of the non-FAR 23 aircraft. I wonder how it worked for the large piston airliners back in the day.
So it looks like every FAR 25 aircraft is required to have surge tanks.
I see from the ATR-42 manual that they follow the regulation for 2%...."An additional volume in each tank allows a 2% thermal expansion of fuel without spillage."
It would be interesting to know if there are surge tanks on an of the non-FAR 23 aircraft. I wonder how it worked for the large piston airliners back in the day.