Go Back  PPRuNe Forums > Flight Deck Forums > Tech Log
Reload this Page >

Eletrical emergency configuration

Wikiposts
Search
Tech Log The very best in practical technical discussion on the web

Eletrical emergency configuration

Thread Tools
 
Search this Thread
 
Old 26th Jan 2018, 10:59
  #1 (permalink)  
Thread Starter
 
Join Date: Jan 2018
Location: Manila
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
Eletrical emergency configuration

hi guys, during ECAM action why is it the APU if avail will be started since AC1 and AC2 are already lost meaning even if the APU will start it still cannot supply any AC busses.

Also, on ground why is it that APU can only be started below 100knots but then again the AC busses are inop.

Thanks.
calden320 is offline  
Old 26th Jan 2018, 19:38
  #2 (permalink)  
 
Join Date: Jun 2014
Location: Mordor
Posts: 335
Likes: 0
Received 0 Likes on 0 Posts
The AC busses are lost, because there are no generators to power them. Once you have started the APU, you should have the AC busses back.
Sidestick_n_Rudder is offline  
Old 26th Jan 2018, 19:43
  #3 (permalink)  
 
Join Date: Feb 2013
Location: UK
Posts: 95
Likes: 0
Received 0 Likes on 0 Posts
If the actual AC1 and AC2 busses fail, then yes, firing up the APU is pointless. However if you have entered Emer Elec because the two engine generators are bust then firing up the APU makes sense as it will be able to power AC1 and AC2.
halfofrho is offline  
Old 26th Jan 2018, 22:19
  #4 (permalink)  
Thread Starter
 
Join Date: Jan 2018
Location: Manila
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
During elec emer the engine generators are not busted but its just the failure of 2 ac busses right? However I do not see ( and it doesnt say) any diagram in the electrical where the APU can supply the aircraft electrical network when the AC busses are inop during elec emer. Thanks for further info.

Guys, Have you seen elec emer diagram where the APU will connect to the aircraft electrical network while AC busses are inop?

Likewise can anyone clarify why the APU can only be started below 100kts on ground while emergency generator is running. Thanks for your help.
calden320 is offline  
Old 27th Jan 2018, 19:04
  #5 (permalink)  
 
Join Date: Nov 1999
Location: UK
Posts: 2,494
Received 105 Likes on 63 Posts
Highly unlikely to have a dead short on both main AC busses simultaneously.

Airbus boffins won’t have written the ECAM to perform useless tasks !
Uplinker is offline  
Old 27th Jan 2018, 22:03
  #6 (permalink)  
 
Join Date: Jun 2014
Location: Mordor
Posts: 335
Likes: 0
Received 0 Likes on 0 Posts
@calden

Elec Emergency Config essentially means loss of all generators. It assumes all AC Buses to be operational, just not powered. Therefore APU start will restore the normal AC power. AC bus loss is a different procedure and I don’t think Airbus even envisaged losing both AC buses at the same time

As for APU start on ground. The system logic is that on ground, you’re not getting enough power from the RAT and DC BAT bus is only connected to the batteries below 100kt. I don’t know the actual reasons for that, but basically if you’re on GND and above 100kt:
- RAT is not available (because min RAT speed is 140kt)
- BAT bus is not yet powered by the batteries

Hence - you can’t start the APU
Sidestick_n_Rudder is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.