B747-400: BAT switch with APU running
Thread Starter
Joined: Nov 2008
Posts: 28
Likes: 0
From: Europe
B747-400: BAT switch with APU running
Good morning folks.
We had a discussion in the cockpit last night regarding what would happen if the BAT switch was turned OFF during ground operations with the APU running, APU generators connected and STBY POWER switch in AUTO. We all imagined that "nothing" would happen, considering that the relevant busses would be fed by the AC system.
Allegedly, someone turned BAT OFF by an accident in mentioned condition and everything went black and the APU subsequently shut down. Could anyone please explain why?
Best regards,
Bluescan
We had a discussion in the cockpit last night regarding what would happen if the BAT switch was turned OFF during ground operations with the APU running, APU generators connected and STBY POWER switch in AUTO. We all imagined that "nothing" would happen, considering that the relevant busses would be fed by the AC system.
Allegedly, someone turned BAT OFF by an accident in mentioned condition and everything went black and the APU subsequently shut down. Could anyone please explain why?
Best regards,
Bluescan
Joined: Sep 2016
Posts: 1
Likes: 0
From: UK
If I recall correctly, the battery bus supplies power to the APU fire protection system. In the scenario you describe the APU goes into an auto shutdown without a cooling cycle as a safety precaution - this is the case on the 757 anyway!

Joined: Feb 2004
Posts: 1,410
Likes: 36
From: Australia
Definitely shuts down the APU. Ask me how I know :P
From my 747-400 manuals:
"Turning the Battery Switch off de-energizes the BCU Standby Power Relay (R7301), which provides a false duct overheat signal to the APUC. The APUC then shuts down the APU. Logic in the EIUs prevents false messages in this situation."
This autoshutdown has no cooldown period.
From my 747-400 manuals:
"Turning the Battery Switch off de-energizes the BCU Standby Power Relay (R7301), which provides a false duct overheat signal to the APUC. The APUC then shuts down the APU. Logic in the EIUs prevents false messages in this situation."
This autoshutdown has no cooldown period.