Dear All.
I am having a unique problem while starting G450 APU, Honeywell 160. It does not pose any problem during initial start but if it is switched on and again tried to start it will not (no ignition but rpm do increase till 22 percent)
As APU cools down it will receive ignite easily.
Muhammad Omar is offline  
Old 17th May 2016, 16:18
  #2 (permalink)  
 
Join Date: Jun 2014
Location: Canada
Posts: 102
Likes: 0
Received 0 Likes on 0 Posts
Not familiar with this particular APU, but this is a pretty common baseline design. (basically a GTCP 36-150)

Primary fuel nozzles need cleaning. Uneven fuel distribution pattern out of the nozzle is snuffing out the ignitor and preventing light-off. First start of the day and after sitting a while the fuel evaporates and ignitor does it's job. But once covered in fuel it prevents spark.

Otherwise unplug the fuel shut-off solenoid and give it start a couple times. Listen for consistent 'cracks' from the ignitors. If it is only working part of the time may be time for new ignitors or ignition exciter.
plhought is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.