NG Display Source
Thread Starter
Joined: Oct 1999
Posts: 1,051
Likes: 0
NG Display Source
Hi
Why would the following symptoms possibly appear;
•No hydraulic pressure indication on the failed side
•Speed limit flag shown on the failed side
•Minimum maneuver speed and stick shaker band removed on the failed side •Both EEC ALTN lights illuminated.
Regards
Pin
Why would the following symptoms possibly appear;
•No hydraulic pressure indication on the failed side
•Speed limit flag shown on the failed side
•Minimum maneuver speed and stick shaker band removed on the failed side •Both EEC ALTN lights illuminated.
Regards
Pin
Joined: Mar 2011
Posts: 27
Likes: 0
From: Middle East
No hydraulic pressure indication on one side typically indicates DEU failure(DEU1 for HydA, DEU2 for HydB). You would probably have a CDS Fault annunciation as well(if on the ground).
I can see how DEU failure could cause the other issues as well, but I haven't personally noticed them in the incidents where I've had DEU issues. They were all on the ground, and MX reset the CB's for the DEU in question, waited about 3 minutes, and all was good. A total power down/power up would accomplish the same.
I can see how DEU failure could cause the other issues as well, but I haven't personally noticed them in the incidents where I've had DEU issues. They were all on the ground, and MX reset the CB's for the DEU in question, waited about 3 minutes, and all was good. A total power down/power up would accomplish the same.
Joined: Sep 2014
Posts: 116
Likes: 0
From: Someone else's acft

Hope this scheme helps you understand the system...
Probably those items are listed as a consequence of a DEU failure, because DEUs gets data from numerous sources (such as ADIRU, thus leading to loss of minimum maneuvering & stick shaker band).
Thread Starter
Joined: Oct 1999
Posts: 1,051
Likes: 0
Thanks
No hydraulic pressure indication displayed could be agreed as a display error by no LOW PRESSURE annunciation and the MFD (Lower display unit) page having no display. Combine both and you can assume you still have normal hydraulics. Also standby RUD would not have come on either?
No hydraulic pressure indication displayed could be agreed as a display error by no LOW PRESSURE annunciation and the MFD (Lower display unit) page having no display. Combine both and you can assume you still have normal hydraulics. Also standby RUD would not have come on either?