Go Back  PPRuNe Forums > Flight Deck Forums > Tech Log
Reload this Page >

NG ETOPS controlling factor

Wikiposts
Search
Tech Log The very best in practical technical discussion on the web

NG ETOPS controlling factor

Thread Tools
 
Search this Thread
 
Old 5th Oct 2015, 01:00
  #1 (permalink)  
Thread Starter
 
Join Date: Oct 1999
Posts: 1,050
Likes: 0
Received 0 Likes on 0 Posts
NG ETOPS controlling factor

Hi

When certified the NG is 180mins ETOPS. Is this because of the cargo fire suppression factor or is it something else?

I thought it would be only 60mins, based on the duration that the battery can give you in the event of double generator failure or does Boeing deem this as very very unlikely, hence the cargo fire extinguisher path.

Regards

Tom
Pin Head is offline  
Old 5th Oct 2015, 13:23
  #2 (permalink)  
 
Join Date: Jun 2013
Location: Or-E-Gun, USA
Posts: 326
Likes: 0
Received 0 Likes on 0 Posts
@Pin Head

This is ONLY a guess, but I think, "Something Else." Cargo fire suppression duration time can be enhanced -if necessary - to achieve ETOPS or extended ETOPS permissions, if/when a carrier wishes to spend the bucks. For cargo fire suppression it not a whole lot more than how much (volume/time) inert diplacement gas is carried. and how it is dispensed. (Of course there is more, but that's the biggie.) There ARE other concerns for ETOPS operations (737? you said??) beyond 60 minutes, but they are more than a bit complicated. Perhaps because of its relatively modest size, until recently the B737 was not a serious contender for extended ETOPS operations. Other considerations include an enhanced maintenance schedule and a proved history of reliability. As the most frequently sold, used and flown transport-class airplane in AV history, I'd guess that the properly equipped, individual B73 is not difficult to certify for extended ETOPS operations. Proof: Several carriers operate the B73 from the Left Coast to Hawaii, several times every day. So... while extended cargo fire suppression is one concern, there are others. The B73 series CAN be equipped for and can qualify for extended ETOPS operations.
No Fly Zone is offline  
Old 5th Oct 2015, 13:27
  #3 (permalink)  
 
Join Date: Jan 2006
Location: US
Posts: 2,205
Likes: 0
Received 0 Likes on 0 Posts
Company said our 737NG's are not 180 ETOPS certified.
misd-agin is offline  
Old 5th Oct 2015, 15:49
  #4 (permalink)  
Thread Starter
 
Join Date: Oct 1999
Posts: 1,050
Likes: 0
Received 0 Likes on 0 Posts
Thanks guys. Just looking big picture really. If you don't have rafts then straight away you cant do 180min.
Pin Head is offline  
Old 5th Oct 2015, 16:17
  #5 (permalink)  
 
Join Date: Mar 2007
Location: USofA
Posts: 1,235
Likes: 0
Received 0 Likes on 0 Posts
The 737G cannot be certified beyond 180 minutes. You need to have the APU running between your ETOPS entry and exit points unless your on a special approval for an APU maintenance program in which case you do not need it to be running. As other have said there is a lot more to this than what is obvious. The fire suppression is the limiting factor.


Many airlines fly the NG between the west coast of the US and PHNL which requires 180' authority.
Spooky 2 is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.