A320 Landing Gear

It is possible to deploy the gear on the Airbus above the relevant limiting speed (260kts on the A320), with a ADIRS failure, electrical failure, hydraulic failure etc etc.???

Can the gear be extended above 260 kts if necessary? If yes, How?
lokeshm11 is offline  
Reply
Old 15th February 2015 | 15:32
  #2 (permalink)  
25 Anniversary
 
Joined: Dec 2000
Posts: 2,132
Likes: 3
From: on the golf course (Covid permitting)
I thought the gear limit was 250 kts?

Why would you want to deploy it above the limit anyway?
TopBunk is offline  
Reply
Old 15th February 2015 | 16:01
  #3 (permalink)  
15 Anniversary
 
Joined: Jul 2007
Posts: 812
Likes: 19
From: uk
TopBunk: I think he is referring to the HYD deactivation speed.
Meikleour is offline  
Reply
Old 15th February 2015 | 16:11
  #4 (permalink)  
 
Joined: Jan 2001
Posts: 187
Likes: 0
From: Australia
ADR 1/3 determine if the current IAS is in excess of 260 kias. If either detects that the speed is higher than this threshold, then a safety valve closes that prevents the gear from being extended until the speed drops below 260 kias.

If ADR 1 + 3 fail, then the 'high speed' signal would not be able to be sent to the safety valve. Airbus have foreseen this and have designed the system to close the safety valve if ADR 1 + 3 fail (see PRO ABN 34 NAV ADR 1 + 3 FAULT). Gear must be extended by gravity and retraction is not available.

I can't find anything conclusive, but would guess that in this circumstance, the gear could be extended at any speed by using the gravity gear extension handle.

The same would then apply to a full HYD, or ELEC failure. It seems that the gravity gear extension system overrides everything.
RAD_ALT_ALIVE is offline  
Reply
Old 15th February 2015 | 19:30
  #5 (permalink)  
15 Anniversary
 
Joined: Mar 2009
Posts: 60
Likes: 0
From: Prague
Agree,if I remeber it correctly,first turn on emer. gear extension handle opens safety valve.
LEVEL600 is offline  
Reply
Old 16th February 2015 | 02:31
  #6 (permalink)  
15 Anniversary
 
Joined: Jun 2007
Posts: 3,443
Likes: 39
From: Wanderlust
LEVEL600
first turn on emer. gear extension handle opens safety valve.
If that were be the case then what is the purpose of gravity extension? Safety valve has nothing to do with emergency extension. Emergency handle cuts off the hydraulics by closing the cut off valve which is after the safety valve. It doesn't use hydraulics.
vilas is offline  
Reply
Old 16th February 2015 | 09:28
  #7 (permalink)  
15 Anniversary
 
Joined: Mar 2009
Posts: 60
Likes: 0
From: Prague
My mistake,you are right, cut off and vent valves are operated by free fall, not safety valve which is pure electrical. I don't expect using hydraulic pressure for gravity extension,but forgot how is hydraulic fluid traped in actuators directed during free fall. Good recurrent for me .

Last edited by LEVEL600; 16th February 2015 at 10:24.
LEVEL600 is offline  
Reply
Old 17th February 2015 | 13:34
  #8 (permalink)  
 
Joined: Mar 2005
Posts: 1,338
Likes: 1
From: Uh... Where was I?
The valve only prevents the system to be pressurized, and therefore prevents the hydraulically extension, but it doesn't prevent the gravity extension, which in my opinion would be possible at any speed.
In fact, I believe one of the effects of activating the gravity system is to open that valve, isn't it?
Microburst2002 is offline  
Reply
Old 17th February 2015 | 14:00
  #9 (permalink)  
15 Anniversary
 
Joined: Mar 2009
Posts: 60
Likes: 0
From: Prague
No for second sentence,I used same bad logic.Safety valve is not part of free fall sequence as Vilas said and can be both open or closed for gravity extension. Free fall is performed without hydraulic pressure, which is shut by cutoff valve, valve installed downstream of safety valve . Free movement of hydraulic fluid in actuators is achieved by two vent valves, one for nose and one for main legs,which allows fluid circulation and return to tank.
LEVEL600 is offline  
Reply

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2026 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.