Go Back  PPRuNe Forums > Flight Deck Forums > Tech Log
Reload this Page >

A320 battery switch off requirements

Wikiposts
Search
Tech Log The very best in practical technical discussion on the web

A320 battery switch off requirements

Thread Tools
 
Search this Thread
 
Old 17th Jun 2014, 07:00
  #1 (permalink)  
Thread Starter
 
Join Date: Jun 2014
Location: colombo
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
A320 battery switch off requirements

what are the requirements to switch off the batteries in A320 when the apu is shut down please need a quick answer for this
suraj1990 is offline  
Old 17th Jun 2014, 08:54
  #2 (permalink)  
 
Join Date: Feb 2002
Location: The Sandpit
Posts: 555
Likes: 0
Received 0 Likes on 0 Posts
You can switch them off whenever you like!

However, there will be at least 2 issues.

1. You won't get any fire warning in the event of a fire post shutdown.

2. The APU inlet door won't close.

Good practice (and the AMM) dictate a 2 minute wait between actual APU shutdown and switching the batteries off.
mono is offline  
Old 17th Jun 2014, 09:12
  #3 (permalink)  
 
Join Date: Jun 2007
Location: Wanderlust
Posts: 3,407
Likes: 0
Received 0 Likes on 0 Posts
suraj1990
Switching of batteries whenever you feel like is a wrong advice. Batteries should not be switched off of for at least 10 seconds after ADRs are switched off to allow them to memorize the last position. Also they should not be switched off before two minutes from the time avail light goes off to prevent smoke in the cabin at the next APU start up.

Last edited by vilas; 17th Jun 2014 at 14:39.
vilas is offline  
Old 17th Jun 2014, 11:21
  #4 (permalink)  
 
Join Date: Apr 2004
Location: United States of Europe
Age: 40
Posts: 502
Likes: 0
Received 0 Likes on 0 Posts
A320 battery switch off requirements

As above!
The 2min wait coincides with the APU flap being closed. (Ps: 2 min is worst case scenario as APU continues to run for 1 min after use of APU bleed)
However it is the actual de-oilling sequence that is the key factor. The flap closes when the de-oilling sequence finishes, hence the association.
Also when APU start is attempted with apu flap still in uncommanded position (ie. incorrect shutdown) this could lead to APU start fault. (Hence a little wait after master on does not hurt)
My 2cts
OPEN DES is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.