B777 External Power/APU

Any idea of the reasoning behind why the Secondary external power drops offline once the APU starts? I assume there is a fuel saving to bring it back online again but always wondered why. There doesn't appear to be any problem operating the APU for Packs only and using ground electric?
irish777 is offline  
Old 12th May 2014, 18:52
  #2 (permalink)  
 
Join Date: Oct 1998
Location: CGK to HKG
Posts: 249
Likes: 0
Received 0 Likes on 0 Posts
Electrical power

On the basis of new for old powers..
When the APU generator is available the APU GCU closes the aux power breaker APB and the Bus Power Contactor Unit BPCU opens the Secondary electrical power contactor EPC. Sec Ext power is removed and the APU generator comes on line to power the left main AC bus and the right main bus via BTB's if the primary ext power is not available.
If both the APU GEN and Primary ext power are available the logic is to use the pri ext power to power the right main AC bus, AC ground handling bus and the ground service bus. the APU GEN will power just the left main AC bus.
Manually selecting the secondary ext power will remove the APU GEN by opening the APB and allow the sec ext power contactor to close and power the left main AC bus. All GCU's and BPCU communicate together on the ARINC 629 bus for correct opening and closing of the breakers and contactors.
Tinwacker is offline  
Old 14th May 2014, 12:21
  #3 (permalink)  
Thread Starter
 
Join Date: Jun 2012
Location: Dubai, UAE
Posts: 42
Likes: 0
Received 0 Likes on 0 Posts
Thanks for the detailed reply.
Is there an approximate figure of fuel saving achieved by re-selecting it and not using the APU for electrics, but only bleed air? I haven't been able to find a fuel rate figure on the maintenance pages.
I only ask out of interest as there often seems to be a reluctance to do this and go to APU electrics as soon as packs are needed on the ground even if external power is provided.
irish777 is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.