Go Back  PPRuNe Forums > Flight Deck Forums > Tech Log
Reload this Page >

B-757 minimum fuel ground

Wikiposts
Search
Tech Log The very best in practical technical discussion on the web

B-757 minimum fuel ground

Thread Tools
 
Search this Thread
 
Old 11th Jun 2013, 15:12
  #1 (permalink)  
Thread Starter
 
Join Date: Apr 2010
Location: Europe
Posts: 12
Likes: 0
Received 0 Likes on 0 Posts
B-757 minimum fuel ground

B-757 AMM:
The three identical heat exchangers are in the wing fuel tanks and use fuel as a coolant. The left and light system heat exchangers are at the inboard end of the left and right main fuel tanks, respectively. The center system heat exchanger is adjacent to the left system exchanger. A minimum of 600 gallons (4020 pounds/1827 kilograms) of fuel is required in each main tank to provide hydraulic fluid cIooling.
Is this restriction applied for flight OR both in flight and on the ground?
Thanks!
Mashuk is offline  
Old 12th Jun 2013, 18:13
  #2 (permalink)  
 
Join Date: Dec 2006
Location: belgium
Posts: 236
Likes: 0
Received 0 Likes on 0 Posts
The minimum amount of fuel is always necessary when your hydraulic systems are on, to provide them with cooling. So yes, both ground and air; however I don't think many flights are having less than 2 tons in the mains when still in the air.
Piper19 is offline  
Old 14th Jun 2013, 17:10
  #3 (permalink)  
Thread Starter
 
Join Date: Apr 2010
Location: Europe
Posts: 12
Likes: 0
Received 0 Likes on 0 Posts
Not 2 tonns.
There should be 1827 kg in EACH main tank. So, 3654kg that apprx 3700 kg.
In accordance with FPPM in might be more than 1.5 hour reserve.
In this case regulation's fuel reserve requirements might be less than manufacture's requirements. That is an item to think about that.
Mashuk is offline  
Old 14th Jun 2013, 17:28
  #4 (permalink)  
 
Join Date: Sep 1999
Location: Middle England
Posts: 611
Likes: 0
Received 0 Likes on 0 Posts
There is no minimum fuel limitation in our 757 FCOM. The "Low Fuel" EICAS comes on with about 1000 kgs remaining in either main tank.
763 jock is offline  
Old 14th Jun 2013, 19:03
  #5 (permalink)  
Thread Starter
 
Join Date: Apr 2010
Location: Europe
Posts: 12
Likes: 0
Received 0 Likes on 0 Posts
I advised AMM information.
FCOM indicate Low Fuel situation. It's different.
Fuel less than indicated in AMM will cause increasing hydraulic liquid temperature and will cause increasing pump temperature in some ambient conditions.
Here is another item to think about...
Mashuk is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.