Go Back  PPRuNe Forums > Flight Deck Forums > Tech Log
Reload this Page >

IGN in Emer Descent


Notices
Tech Log The very best in practical technical discussion on the web

IGN in Emer Descent

Old 13th June 2012 | 11:04
  #1 (permalink)  
Thread Starter
 
Joined: Jan 2012
Posts: 20
Likes: 0
From: Swindon
IGN in Emer Descent

Why is there the requirement for switching on the Ignition in an Emergency Descent?
Obviously airmanship wise it's never going to be a bad idea but anyone with more than that to add?
Cheers
CC1
clonecity1 is offline  
Reply
Old 13th June 2012 | 11:17
  #2 (permalink)  
 
Joined: Dec 2003
Posts: 293
Likes: 0
From: Out there
Depends on aircraft type and what problem there is!
Baywatcher is offline  
Reply
Old 13th June 2012 | 11:28
  #3 (permalink)  
25 Anniversary
 
Joined: Jan 2001
Posts: 609
Likes: 1
From: Around the world.
For example, on a CFM56, it is detrimental to select ignition in almost any case according to CFM.... reason being it can detect a flame out more quickly than each spark on continuous; and if the spark is required due flameout there is a higher voltage available thus a stronger spark available in a fraction of a second due to not continually discharching the capacitors in the ignitor box. At the airline I work at it is SOP to select ignition on the CFMs in Emer descent... no idea why.
tom775257 is offline  
Reply
Old 13th June 2012 | 11:30
  #4 (permalink)  
15 Anniversary
 
Joined: Jan 2008
Posts: 2,296
Likes: 305
From: All at sea
Probably because you are at idle thrust and don't know what conditions you may encounter on the way down. With all the chaos around, you may not be thinking (or have time to think) 'icing', so it seems like a good idea, regardless of type.
Mach E Avelli is offline  
Reply
Old 13th June 2012 | 11:51
  #5 (permalink)  
15 Anniversary
 
Joined: Mar 2006
Posts: 134
Likes: 6
From: expat
Just follow QRH.
Otherwise we end up with a whole other virtual manual of opinions to muddy the waters. If you really think you have a great idea get your tech or training dept to ask the manufacturer.
HPSOV L is offline  
Reply
Old 13th June 2012 | 12:04
  #6 (permalink)  
15 Anniversary
 
Joined: Jun 2006
Posts: 1,204
Likes: 26
From: Australia
ust follow QRH.
Otherwise we end up with a whole other virtual manual of opinions to muddy the waters. If you really think you have a great idea get your tech or training dept to ask the manufacturer.
That is a pretty negative unhelpful comment to a perfectly reasonable question.
Tee Emm is offline  
Reply
Old 13th June 2012 | 12:13
  #7 (permalink)  
Thread Starter
 
Joined: Jan 2012
Posts: 20
Likes: 0
From: Swindon
Now, now HP, let's display some of that CRM your type are renowned for..Tech Log old boy, on a professional pilots' rumour network.

You best keep it simple for yourself and never wonder why.
clonecity1 is offline  
Reply
Old 13th June 2012 | 13:54
  #8 (permalink)  
15 Anniversary
 
Joined: Mar 2006
Posts: 134
Likes: 6
From: expat
Ahem...
missed the point of the original post. Apologies.
Agree with MachE, though alot of modern engines have auto this and that so not as much a consideration as in the past.

Last edited by HPSOV L; 13th June 2012 at 13:59.
HPSOV L is offline  
Reply
Old 13th June 2012 | 13:59
  #9 (permalink)  
 
Joined: Apr 2010
Posts: 0
Likes: 0
From: Home soon
For example, on a CFM56, it is detrimental to select ignition in almost any case according to CFM.... reason being it can detect a flame out more quickly than each spark on continuous; and if the spark is required due flameout there is a higher voltage available thus a stronger spark available in a fraction of a second due to not continually discharching the capacitors in the ignitor box
Would you mind posting your CFM reference for this post?
Thanks.
de facto is offline  
Reply
Old 13th June 2012 | 16:41
  #10 (permalink)  
25 Anniversary
 
Joined: Jan 2001
Posts: 609
Likes: 1
From: Around the world.
I'm trying to find it for you, I had it in a presentation somewhere I am sure but no joy so far, I thought it was in a CFM ops seminar but can't see a reference now (unless I'm completely loosing the plot and thinking of the V2500). Any one else know?

Looking through the CFM seminar, if it detects any decel greater than expected on normal schedule (among other things) it will immediately engage dual ignition anyway.

Last edited by tom775257; 13th June 2012 at 16:45.
tom775257 is offline  
Reply
Old 13th June 2012 | 17:35
  #11 (permalink)  
 
Joined: Aug 2008
Posts: 28
Likes: 0
From: Romania
@Tom
Autoignition is available only on 737 - NG ( CFM 56 -7).
On the classics CFM 56 -3 you don't have this feature ; in order to keep the commonality between CL and NG you have to put them on continous.
Hope it helps
B737-pilot is offline  
Reply
Old 13th June 2012 | 17:40
  #12 (permalink)  
50 Countries Visited
10 Anniversary
 
Joined: Sep 2011
Posts: 351
Likes: 148
From: FL390
I had the impression that ignition is fairly important in a lot of circumstances on the V2500, given that you only have to sneeze and the ignition comes on.
Fursty Ferret is offline  
Reply
Old 13th June 2012 | 19:48
  #13 (permalink)  
 
Joined: Dec 1999
Posts: 2,584
Likes: 0
From: UK
Jeeesus!

If the QRH says so, fekkin do it!

What on earth is so hard to understand about that?

I know we descend at idle with no ignitors on every day, but are some of you some kind of self-appointed galactic test pilot who knows more about this than the manufacturer's test pilots do? Which TP school do you come from - do tell...

If such superior Test Pilot please speak up.

If not, kindly shut up and let the rest of us Professional pilots follow the checklist. Gobshyte fools.
Agaricus bisporus is offline  
Reply
Old 13th June 2012 | 19:57
  #14 (permalink)  
 
Joined: Mar 2002
Posts: 4,569
Likes: 1
From: Florida
Agree with QRH discussions but.... the question was posed as to why the procedure? That I interpret is a legitimate question to underrstand the reasoning behind it, rather than to challenge that it is wise to follow or not.

Somewhere in the vitrolic above are some excellent points that may or may not apply to the machine that you fly.
lomapaseo is offline  
Reply
Old 14th June 2012 | 03:35
  #15 (permalink)  
 
Joined: Apr 2010
Posts: 0
Likes: 0
From: Home soon
Jeeesus!

If the QRH says so, fekkin do it!

What on earth is so hard to understand about that?

I know we descend at idle with no ignitors on every day, but are some of you some kind of self-appointed galactic test pilot who knows more about this than the manufacturer's test pilots do? Which TP school do you come from - do tell...

If such superior Test Pilot please speak up.

If not, kindly shut up and let the rest of us Professional pilots follow the checklist. Gobshyte fools.
A great display of pure idiocy.
I suggest you start running and see a specialist
de facto is offline  
Reply
Old 14th June 2012 | 06:09
  #16 (permalink)  
 
Joined: Aug 2008
Posts: 666
Likes: 0
From: Betwixt and between
Why is there the requirement for switching on the Ignition in an Emergency Descent? Obviously airmanship wise it's never going to be a bad idea but anyone with more than that to add?
I suspect it is simply a risk mitigation measure. An emergency descent is a busy time and descent through icing is likely and through unknown or unconsidered levels of precipitation is quite possible too.

Given the possible slow reaction by the crew due to workload and those potential changes in the outside environment, I think it should be judged an essential safety measure.
Sciolistes is offline  
Reply
Old 14th June 2012 | 13:14
  #17 (permalink)  
Thread Starter
 
Joined: Jan 2012
Posts: 20
Likes: 0
From: Swindon
unstable retards

Thank you to those who offered considered opinions to a question posed out of curiosity. Nothing more sinister than that I'm afraid.

To those frustrated,aggressive,intellectually challenged losers, you are a disgrace.

If ever there was a thread that exposed the effects of the proliferation of the pilot license to the Neanderthals, this is it.

I'm just starting out in this profession and hope the Captains I will have to fly with will be from a more robust selection process.

CC1 is now retiring.
clonecity1 is offline  
Reply

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Thread Tools
Search this Thread

Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2026 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.