QRH procedure for "PACK" of B737-800

In the even of both packs tripped off, according to QRH, after we descent at or below 10,000' , we're instructed to put Pressurization mode Selector to MAN, and fully open the outflow valve to increase airplane ventilation.

Anyone knows why then we turn R recirculation fan switch to AUTO, and L recirculation fan to OFF? If we are to open the overboard exhaust valve, aren't we supposed to turn the R recirculation fan switch to OFF instead of the L one?
heart1 is offline  
Old 22nd Aug 2011, 03:18
  #2 (permalink)  
 
Join Date: May 2011
Location: Seoul, South Korea
Age: 43
Posts: 31
Likes: 0
Received 0 Likes on 0 Posts
I don't know the answer to your question, but the following statement (extracted from AMM Part I Chapter 21) suggests that the issue is smoke control:

"The air conditioning overboard exhaust valve reconfig cont circuit breaker is for unpressurized dispatch. If the circuit breaker is open, the bypass circuit enables the recirculation fan to operate if the smoke control relay R648 energizes. The smoke control relay is energized during these conditions:

* Left or right pack switch is in HIGH

* Airplane is in the air

* R RECIRC FAN switch is off.

See the overboard exhaust valve system for more information about the smoke control relay. (SECTION 21-27)"

As I mentioned above, R/H recirculation fan can operate even though R/H RECIRC Fan switch is turned off

Refer to DDG21-01-01-06(M.O)


OEV automatically fully open during unpressurized flight(differential press less than 1psid) when R/H fan switch is in AUTO

Regards,

PS
I have been also researching and digging the question like you.

Last edited by DongJoon Choi; 22nd Aug 2011 at 03:53.
DongJoon Choi is offline  
Old 27th Aug 2011, 08:00
  #3 (permalink)  
Thread Starter
 
Join Date: Jul 2011
Location: Taiwan
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
Thank you for your reply. Think the OEV is working under normal mode instead of smoke removal mode. The abnormal procedure seems to make more sense to me now. Many thanks.
heart1 is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.