Go Back  PPRuNe Forums > Flight Deck Forums > Tech Log
Reload this Page >

Enough Oxygen?

Wikiposts
Search
Tech Log The very best in practical technical discussion on the web

Enough Oxygen?

Thread Tools
 
Search this Thread
 
Old 19th Jul 2010, 14:20
  #1 (permalink)  
Thread Starter
 
Join Date: Apr 2010
Location: Europe
Posts: 7
Likes: 0
Received 0 Likes on 0 Posts
Enough Oxygen?

I recently travelled from LHR to HKG on an NZ 777.

I was more than a little surprised to see that we followed the Y1 route to the south of Urumqi.

An area with MSA's in excess of 20,000. I know the 777 can maintain that engine out, but what about the oxygen requirements.

Looking at a map there must be a position along that route where it would take longer than 15-20 minutes (chemical oxygen) to get to a 14,000 MSA.

What's the deal
737superace is offline  
Old 19th Jul 2010, 14:32
  #2 (permalink)  
 
Join Date: Oct 2009
Location: UK
Posts: 1,270
Likes: 0
Received 0 Likes on 0 Posts
Are you sure it's chemical oxygen - and not supplied from large bottles of O2 held in the hold giving the legal duration required?
rudderrudderrat is offline  
Old 19th Jul 2010, 14:45
  #3 (permalink)  
 
Join Date: Mar 2000
Location: Sunrise Senior Living
Posts: 1,338
Likes: 0
Received 0 Likes on 0 Posts
It's all part of performance planning.

mcdhu
mcdhu is offline  
Old 19th Jul 2010, 16:16
  #4 (permalink)  
 
Join Date: Aug 1998
Location: Ex-pat Aussie in the UK
Posts: 5,795
Received 116 Likes on 56 Posts
The 737-300 and up uses generators, 20 mins is standard, 40 mins is an option for operations in high terrain areas.

The 737-1/200 and 747 uses bottles, and I wouldn't be surprised if the 777 was the same.
Checkboard is offline  
Old 19th Jul 2010, 17:13
  #5 (permalink)  
 
Join Date: Jul 2001
Location: Over there.
Posts: 186
Likes: 0
Received 0 Likes on 0 Posts
The 777 uses standard 22 minute chemical generators.
INLAK is offline  
Old 19th Jul 2010, 17:19
  #6 (permalink)  
 
Join Date: Sep 1998
Location: wherever
Age: 55
Posts: 1,616
Likes: 0
Received 0 Likes on 0 Posts
Piece of cake. Thats what escape routes are for.
FE Hoppy is offline  
Old 19th Jul 2010, 17:19
  #7 (permalink)  
 
Join Date: Jul 2010
Location: France
Posts: 8
Likes: 0
Received 0 Likes on 0 Posts
737superace said: "An area with MSA's in excess of 20,000. I know the 777 can maintain that engine out, but what about the oxygen requirements.
"


It also has something to do about the extend of that 20K ft MSA.
a.mandon is offline  
Old 19th Jul 2010, 21:16
  #8 (permalink)  
 
Join Date: Jun 1997
Location: auckland, new zealand
Posts: 224
Likes: 0
Received 0 Likes on 0 Posts
Inlak
Your 777 may use chemical generators, Air NZ's use gaseous (ANZ FCOM 1.40.8)
cribble is offline  
Old 19th Jul 2010, 23:22
  #9 (permalink)  
 
Join Date: Feb 2010
Location: a shack on a hill
Posts: 128
Likes: 0
Received 0 Likes on 0 Posts
As far as I know, L888 is the most critical airway. All others are within O2 generator certification limits, but that is a fake. Check the flow rate and you will find, that after one half to two thirds of the flow time the rate is insufficient to maintain a healthy adult.
heavy.airbourne is offline  
Old 20th Jul 2010, 05:03
  #10 (permalink)  
 
Join Date: Aug 2006
Location: South
Posts: 638
Received 0 Likes on 0 Posts
Air NZ's use gaseous
Yes the Air NZ B772 and also the B773 have the gaseous O2 system.
c100driver is offline  
Old 20th Jul 2010, 09:10
  #11 (permalink)  
 
Join Date: May 2008
Location: South West Pacific
Posts: 27
Likes: 0
Received 0 Likes on 0 Posts
A check is done prior to each flight over the sector. The total Pax and F/D Oxygen pressure, which are contained in two separate bottle systems, has the pressure recorded and then corrected for local OAT temperature. This corrected pressure is then compared with the amount needed for
flight over the Y1 Route depending on the passenger cabin payload and flight deck complement. There are 304 seats plus up to 11 cabin crew (normal complement of 10) and the infants equates to depending on the number of passengers on the day to x amount of pressure required. Similarly for the F/D there needs to be y amount of pressure depending on whether there are 2, 3 or 4 occupants on the flight deck. If the pressure is below that required there are two choices, either a top up or alternatively it is the long way around.
ghw78 is offline  
Old 20th Jul 2010, 12:33
  #12 (permalink)  
 
Join Date: Sep 1999
Location: ME
Posts: 5,502
Likes: 0
Received 0 Likes on 0 Posts
Check the flow rate and you will find, that after one half to two thirds of the flow time the rate is insufficient to maintain a healthy adult.
Would you care to expand on this statement? Is this the reason our 180 minutes ETOPS was reduced to 159 minutes?

Mutt
mutt is offline  
Old 22nd Jul 2010, 20:39
  #13 (permalink)  
Thread Starter
 
Join Date: Apr 2010
Location: Europe
Posts: 7
Likes: 0
Received 0 Likes on 0 Posts
Fine!

That's all great
So when when all the x's and y's etc are all lined up, bottom line . . . . .how many minutes oxygen do you have?
737superace is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.