Hydraulics
Thread Starter
Joined: Sep 2006
Posts: 34
Likes: 0
From: uk
hm I was wondering more about perpetual running of a service say gear that keeps cycling up and down continually. I expect like any fluid there would be expansion and like you said heat generated. Would heat alter the properties of the fluid?
Joined: May 2001
Posts: 10,804
Likes: 1
Aye it can and does.
This from a hydralic ram side of things with earth movers and diggers.
If its old fluid it will have a fair bit of water in it which will boil and cause cavitation in the pumps. which knackars them pretty quickly. If it really gets hot you will start melting seals.
Hydralic fluid is dangeous stuff when hot it sticks to you like nepalm and has quite a large heat capacity. I was never brave enough to do the last couple of threads of the tank plug with my fingers and try and snatch the plug from dropping in the 50 gallon drum.
From a flying side of things I have had a pump explode in the hot section dumping the entire lot in there and thankfully it didn't go on fire. Produced vast quantities of smoke though.
This from a hydralic ram side of things with earth movers and diggers.
If its old fluid it will have a fair bit of water in it which will boil and cause cavitation in the pumps. which knackars them pretty quickly. If it really gets hot you will start melting seals.
Hydralic fluid is dangeous stuff when hot it sticks to you like nepalm and has quite a large heat capacity. I was never brave enough to do the last couple of threads of the tank plug with my fingers and try and snatch the plug from dropping in the 50 gallon drum.
From a flying side of things I have had a pump explode in the hot section dumping the entire lot in there and thankfully it didn't go on fire. Produced vast quantities of smoke though.
Joined: Jun 2010
Posts: 64
Likes: 0
From: england
From a flying side of things I have had a pump explode in the hot section dumping the entire lot in there and thankfully it didn't go on fire. Produced vast quantities of smoke though
Dog Tired
Joined: Oct 2001
Posts: 1,686
Likes: 2
From: uk
A320. Let us imagine, after landing, Y sys runs the aft cargo door opening and fails to shut off. It takes about forty minutes to overheat and pop the cb. You are about to call for engine start...
You then have to wait an hour or so for the sys to reset.
Buggah.
You then have to wait an hour or so for the sys to reset.
Buggah.

Joined: Aug 2000
Aviation Qualifications: Spotter
Posts: 2,143
Likes: 4
From: EGGW
A number of aircraft have what you could call heat exchanges in the fuel tanks.
The hydraulic fluid passes through the matrix/heat exchanger which cools the fluid down.
Not uncommon for a minimum fuel quantity to be required inside fuel tanks, to allow hydraulics to be operated.
The hydraulic fluid passes through the matrix/heat exchanger which cools the fluid down.
Not uncommon for a minimum fuel quantity to be required inside fuel tanks, to allow hydraulics to be operated.
Registered User **
Joined: Mar 2009
Posts: 480
Likes: 0
From: USA
Could repeated running of a hydraulic system cause overheating of hydraulic fluid? if so what would be the possible implications of this?
Now the most common cause of an overheat is due to an actuator failure where fluid that is normally contained on either side of a piston slips by at super high speeds thus friction thus heat.
All aircraft I know of have a means of monotoring hyd temp, if you are concerned about long term usage on the ground just keep an eye on the temperature and give her a break if need be.
Implications.
The pumps and seals take the highest toll soo pump failure, component failure or leakage is possible.


Joined: Jan 2001
Posts: 1,693
Likes: 161
From: home
Was there not an Air France A340 that burnt out because of continuous running of an hydraulic pump on the ground.
Edited to add: ASN Aircraft accident Airbus A340-211 F-GNIA Paris-Charles de Gaulle Airport (CDG)
Edited to add: ASN Aircraft accident Airbus A340-211 F-GNIA Paris-Charles de Gaulle Airport (CDG)