ERJ190 elec hydraulic pump2 operation logic

On ERJ190, elec hydraulic pump2 has a very special operation logic,
it says :
On ground the elec hydraulic pump 2 will be automatically activated when following condiion occur
1.Eng 1 running and parking brake released
I can understand this no problem.
2.During eng1 start(once N2 reaches 40%) if parking brake has been applied within the last 6 min.
note: the elec hydraulic pump 2 will be automatically turn off after 6 min have elapsed from parking brake application.
Can anyone help me to decode condition 2 ?
kuobin is offline  
Old 1st Jun 2010, 09:58
  #2 (permalink)  
 
Join Date: Sep 1998
Location: wherever
Age: 55
Posts: 1,616
Likes: 0
Received 0 Likes on 0 Posts
On ERJ190, elec hydraulic pump2 has a very special operation logic,
it says :
On ground the elec hydraulic pump 2 will be automatically activated when following condiion occur
1.Eng 1 running and parking brake released
I can understand this no problem.
2.During eng1 start(once N2 reaches 40%) if parking brake has been applied within the last 6 min.
note: the elec hydraulic pump 2 will be automatically turn off after 6 min have elapsed from parking brake application.
Can anyone help me to decode condition 2 ?
Yes :-)

The logic to make ACMP2 run includes the questions

1)Is ENG 1 running and Eng 2 OFF? This is yes if the N2 of Eng 1 is >40% and Eng 2 OFF.

2)Has the parking brake gone from off to on in the last 6 minutes?

3)Is the Parking brake OFF?

IF 1 and (2 or 3) is true the pump will run.

The idea is that the pump runs whenever you taxi with Eng 1 running and eng 2 shutdown, but will continue to run if you stop for a short period (< 6minutes)in the taxi. The keep running logic is to stop the pump cycling on and off during a long que of traffic when you are stop and starting a lot.


Because of how the logic is implemented if the parking brake is off or has been applied in the last 6 minutes the second part of the run logic is true (2 or 3) so when you start Eng 1 first you will then complete the logic part 1 and the pump will run for whatever part of the 6 minutes since the brake was appilied remains.
FE Hoppy is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.