B777 Adp
Thread Starter
Joined: Mar 2007
Posts: 1,235
Likes: 0
From: USofA
B777 Adp
I should know this but for the life of me I can document this. Do "both" ADP's run from approximately 60kts to the end of flaps/slat retraction, or does only the left pump run?
Thanks in advance
Thanks in advance
Last edited by Spooky 2; 31st October 2009 at 19:38.
Usual disclaimers apply!
Joined: Nov 1999
Posts: 843
Likes: 0
From: EGGW
Both ADP's will run on the take-off roll and will turn off something like 10 secs after airborne. (Engine failure (bleed loss) and TAC operation).
Both ADP's will run for u/c retraction.
Both ADP's will run for stall protection (autoslats)
One ADP will run in the landing mode from approx. 30ft AGL until a few secs (5?). after the speed brake lever is stowed.
One ADP will run during landing gear extension and flap operation.
Pump operation logic is BOTH in AUTO single pump operation the (HYDIM cards select which pump to equalise wear).

i think!
Both ADP's will run for u/c retraction.
Both ADP's will run for stall protection (autoslats)
One ADP will run in the landing mode from approx. 30ft AGL until a few secs (5?). after the speed brake lever is stowed.
One ADP will run during landing gear extension and flap operation.
Pump operation logic is BOTH in AUTO single pump operation the (HYDIM cards select which pump to equalise wear).

i think!