Go Back  PPRuNe Forums > Flight Deck Forums > Tech Log
Reload this Page >

ATR Airframe Airbleed FAULT! questions to engineers??

Wikiposts
Search
Tech Log The very best in practical technical discussion on the web

ATR Airframe Airbleed FAULT! questions to engineers??

Thread Tools
 
Search this Thread
 
Old 1st Oct 2009, 16:11
  #1 (permalink)  
Thread Starter
 
Join Date: May 2005
Location: varies..a lot
Posts: 339
Likes: 0
Received 0 Likes on 0 Posts
ATR Airframe Airbleed FAULT! questions to engineers??

Hey guys, have an issue u may be able to answer:
In the event of airframe airbleed fault light on the pb, the cause maybe overheat in the duct before the de-ice valve OR a leak in the common airframe air duct after the isolation valve!

Checklist says to deselect the airframe airbleed pb to close the isolation valves, and as long as the engine de-ice is selected on, the de-ice valves will stay open....theory is if there is an overheat, the de-ice valve would have closed and a fault light will appear on the engine de-ice push button, therefore u can determine the side and the overheat problem.

Thats fine and makes sense! But what would u see on the panel if u did not deselect the airframe airbleed pb??? surely if the fault was due to a leak in the common manifold, NO fault light would appear in the engine de-ice system, just a fault light on airframe airbleed and airframe push buttons!

Just trying to figure out the need to de-select FIRST the airframe airbleed push button?
Any info be great IT IS DOING MY HEAD IN!!!

Just an add on: is the closing of one de-ice valve due to overheat enough to create a drop in pressure in the common air bleed manifold, therefore triggering the fault light on the airframe airbleed pb? therefore impossible to tell if the fault detected is due to low pressure created by a leak or an overheat causing a de-ice valve to close? therefore the need to deselect the airfarme airbleed p/b................

Would a leak in the manifold ALSO set the fault light on the engine de-ice push buttons? Really that is my question, because if u get no fault light there, the fault MUST be a leak in the common airgrame bleed manifold!

Last edited by powdermonkey; 1st Oct 2009 at 16:24.
powdermonkey is offline  
Old 2nd Oct 2009, 05:42
  #2 (permalink)  
 
Join Date: Mar 2000
Location: australia
Posts: 121
Likes: 0
Received 0 Likes on 0 Posts
Some of these valves are "Pressure Actuated" , as well as "Electrically actuated." I think the Check list is formulated to ensure that there's a remedy should one or more of these valves stay open in the event of a duct leak , so the drill calls for deselecting them electrically to ensure the valve is closed.
crocodile redundee is offline  
Old 16th Apr 2010, 23:18
  #3 (permalink)  
 
Join Date: Sep 2009
Location: Warsaw, Poland
Age: 47
Posts: 20
Likes: 0
Received 0 Likes on 0 Posts
If you have an "overheat" problem which comes from air temp measured upstream of the de-ice valves or "leak" problem which comes from pressure sensors placed downstream of the de-ice valves the CCAS is activated and AFR AIR BLEED FAULT LIGHT illuminates amber.
The other lights on DE-ICE panel will stay extinguished.
In order to determine what causes the problem we need to deselect AFR AIR BLEED pb. Now, if there was an overheat problem associated ENG pb would illuminate FAULT. If no light illuminates while AFR AIR BLEED is selected off, the reason is leak or low pressure.

Thats my understanding.
Luckystar77 is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.