Can someone explain how on the 737NG, while the aircraft is in a cold and dark state, the elevators remain in the neutral position, how is this done if the hydrauics are (obviosly) depressurized? Im assuming it goes into manual reversion after hydraulic pressure is no longer available, so wouldnt the elevator droop downwards kind of like ERJs? Also one more question, how are the flight controls proteced from wind gusts if the hydrauics are depressurized?
Thanks,
Tyler
Thanks,
Tyler

Joined: Feb 1999
Posts: 813
Likes: 16
From: MAN
T -
Has to do with an accumulator that (should) maintain the position of the flight controls while on a turn around. Does not always work in gusty conditions or after a significant period of time. In adition the elevator is more neutrally balanced.
Has to do with an accumulator that (should) maintain the position of the flight controls while on a turn around. Does not always work in gusty conditions or after a significant period of time. In adition the elevator is more neutrally balanced.
Warning Toxic!
Disgusted of Tunbridge
Disgusted of Tunbridge
Joined: Jan 2005
Posts: 4,011
Likes: 1
From: Hampshire, UK
Without hydraulic pressure, the elevator control can move backwards and forwards in a tailwind quite slowly, but strongly- annoying if you are sitting there, so one normally gets an electric pump on quickly to lock it at neutral. Apparently Boeing assure that no gust locks are needed and no damage will be caused.
Fleet Manager

Joined: Apr 2001
Aviation Qualifications: ATPL
Posts: 7,448
Likes: 310
From: various places .....
Intemperate use of naughty words is not appropriate to this forum .. and probably not the wider site .. Dogma is having a short R&R in the sin bin for the purposes of navel contemplation ... the other posts are not relevant with Dogma's posts suppressed so have been removed to keep some semblance of thread flow.
Joined: Apr 2005
Posts: 569
Likes: 0
From: Stockholm Sweden
The B737 Elevator (and ailerons) are connected with cables to the control column. With no hyd power they will droop an inch or so until the stops in the PCU are contacted. They will then stop unless wind pushes them around.
Nearly every other airliner has fully powered controls. These will droop right down under gravity as the hyd pressure dissapates, this may take an hour or two, or with a small leak in the PCU will take a few minutes.
The B737 is showing its connection to its grandfather, with steel cables and manual reversion.
Nearly every other airliner has fully powered controls. These will droop right down under gravity as the hyd pressure dissapates, this may take an hour or two, or with a small leak in the PCU will take a few minutes.
The B737 is showing its connection to its grandfather, with steel cables and manual reversion.
Thread Starter
Joined: May 2007
Posts: 20
Likes: 0
From: texas
Hey guys thanks a lot for the replies. One more question though, how do the PCU stops only let the flight controls droop about an inch or so, when the actual amount of deflection is much more during normal operation with the hydraulics pressurized? Anyone have a close up pic of the PCU or a detailed diagram so I can see a little better how it works.
thanks again,
Tyler
thanks again,
Tyler

Joined: Apr 2004
Posts: 775
Likes: 2
From: near EDDF
Originally Posted by allflight57
... how do the PCU stops only let the flight controls droop about an inch or so, when the actual amount of deflection is much more during normal operation with the hydraulics pressurized? Anyone have a close up pic of the PCU or a detailed diagram so I can see a little better how it works.
Wiht hydraulic power available, the complete PCU moves to actuate the elevator.
Without hydraulic power you actuate the (weight balanced) elevator mechanically, but you have a kind of "lost motion" until the primary input crank hit the mechanical stops.
So on ground, when you switch of the hydraulic, the elevator drop a little bit.