Wink A320 - Elec Emer Config

Today I was replaying the Electrics Sys of A320 CBT for the third time, but I didn't hear nothing about a secondary nature of this failure.
As you already know, Emer Elec Config. may be mainly caused either by a Dual Generator Failure or Dual AC Bus Fault ... so my question is:
- Which kind of other failure, if any, may bring the aircraft to Emerg Elec Conf. ?

Thanks in advance,
captain87

Last edited by captain87; 3rd June 2008 at 20:24.
captain87 is offline  
Reply
Old 2nd June 2008 | 19:32
  #2 (permalink)  
 
Joined: Mar 2006
Posts: 1,974
Likes: 0
From: Choroni, sometimes
Accelarate to 250 kts or so, pull full aft, then you know....
hetfield is offline  
Reply
Old 2nd June 2008 | 19:39
  #3 (permalink)  
 
Joined: Jul 2007
Posts: 136
Likes: 0
From: In a house
Smoke Drill...
electricdeathjet is offline  
Reply
Old 2nd June 2008 | 19:55
  #4 (permalink)  
Thread Starter
 
Joined: Apr 2007
Posts: 84
Likes: 0
From: Italy
Wink

Thanks a million electricdeathjet !
Smoke drill is the "missing item" I was try to remember and fortunately you remind me this before going back on the FCOM's ...

Best Regards,
captain87

Last edited by captain87; 3rd June 2008 at 05:54.
captain87 is offline  
Reply
Old 3rd June 2008 | 09:16
  #5 (permalink)  
25 Anniversary
 
Joined: May 2000
Posts: 1,021
Likes: 2
From: Glorious West Sussex
AC BUS 1+2 FAIL will also do it.
TyroPicard is offline  
Reply
Old 3rd June 2008 | 20:21
  #6 (permalink)  
Thread Starter
 
Joined: Apr 2007
Posts: 84
Likes: 0
From: Italy
Wink re from captain87

Hi TyroPicard,
for sure, AC Bus 1 + 2 Fault is obviously the main cause of Elec Emer Config. so I decided not to write it ...
In that situation, QRH procedures instruct the pilots to try to reset both of engine generators (if I don't get wrong) then (if unsuccessfull) to isolate both of sides by setting the Bus Tie switch off and trying to reset generator again ... but this may be considered as a "Dual Gen Failure" even though it's not so at all ... Is that correct ?

Lots of Thanks,
captain87
captain87 is offline  
Reply
Old 4th June 2008 | 14:29
  #7 (permalink)  
25 Anniversary
 
Joined: May 2000
Posts: 1,021
Likes: 2
From: Glorious West Sussex
You can have 2 serviceable Gens but still lose AC BUS 1+2 due to an electrical fault, hence the isolation on the second attempt at Gen reset.
But if both Gen are Inop the effect is the same .. but the APU Gen might connect.
TP
TyroPicard is offline  
Reply
Old 4th June 2008 | 14:50
  #8 (permalink)  
Thread Starter
 
Joined: Apr 2007
Posts: 84
Likes: 0
From: Italy
re from captain87

That's all clear now ! Thank you TyroPicard !

Best Regards,
captain87
captain87 is offline  
Reply

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Thread Tools
Search this Thread

Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2026 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.