Go Back  PPRuNe Forums > Flight Deck Forums > Tech Log
Reload this Page >

Starting first engine ... but APU dies !

Wikiposts
Search
Tech Log The very best in practical technical discussion on the web

Starting first engine ... but APU dies !

Thread Tools
 
Search this Thread
 
Old 3rd May 2008, 17:37
  #1 (permalink)  
Thread Starter
 
Join Date: Jan 2005
Location: W of 30W
Posts: 1,916
Likes: 0
Received 0 Likes on 0 Posts
Starting first engine ... but APU dies !

Fuel is already ignited but N rotations are still low when APU auto shutdown ...
What's next ?
CONF iture is offline  
Old 3rd May 2008, 17:42
  #2 (permalink)  
 
Join Date: Sep 2007
Location: Among camels and dunes
Posts: 425
Likes: 0
Received 0 Likes on 0 Posts
Engine master off quickly, call ground.
Jetjock330 is offline  
Old 3rd May 2008, 17:49
  #3 (permalink)  
 
Join Date: Feb 2008
Location: Standby...call you back..
Posts: 210
Likes: 0
Received 0 Likes on 0 Posts
Usually,

Fuel >>cut off

Motoring engine when rpm adequate to blow out the remaining fuel...

Inspect all with maintenance afterwood...
roljoe is offline  
Old 3rd May 2008, 17:57
  #4 (permalink)  
 
Join Date: Jul 1999
Location: Big Sky Country
Posts: 134
Likes: 0
Received 0 Likes on 0 Posts
depends how much you want to get home...continue start, monitor egt and rpm's for increase.
LME (GOD) is offline  
Old 4th May 2008, 05:30
  #5 (permalink)  
 
Join Date: Feb 2006
Location: Rekyavik
Posts: 11
Likes: 0
Received 0 Likes on 0 Posts
In response to LME (Sub-God) from Zeus!!

Suggest continue with the start to see if engine starts WITHIN limits. If start OK, then continue with X-bleed. If not, then shut down & go to hotel! V. easy.
HA56
Hardass56 is offline  
Old 4th May 2008, 05:32
  #6 (permalink)  
 
Join Date: Feb 2006
Location: Rekyavik
Posts: 11
Likes: 0
Received 0 Likes on 0 Posts
LME,
Pls dont take me 2 seriously!!
HA56
Hardass56 is offline  
Old 4th May 2008, 15:46
  #7 (permalink)  
 
Join Date: Jul 1999
Location: Big Sky Country
Posts: 134
Likes: 0
Received 0 Likes on 0 Posts
don't worry hardarse...i never take pilots seriously....a modern fadec engine should be able to cope if it makes it to light off.....it might just be slow to spool up to idle
LME (GOD) is offline  
Old 4th May 2008, 16:24
  #8 (permalink)  
Thread Starter
 
Join Date: Jan 2005
Location: W of 30W
Posts: 1,916
Likes: 0
Received 0 Likes on 0 Posts
So, main risk is EGT rising over limit ... HOT START

If manual start, operator will have to cut off fuel before EGT red mark.
If automatic sequence, FADEC should do the same ...

Any chance of tail pipe fire ... ?
CONF iture is offline  
Old 4th May 2008, 16:49
  #9 (permalink)  
 
Join Date: Mar 2008
Location: Canada
Posts: 20
Likes: 0
Received 0 Likes on 0 Posts
Starting First Engine

Required action depends on Company SOPs and also dependant on how low are the N1,N2 and N3 readings. No specific numbers are available in any AMM but the start can be continued but being very very watchfull as long as the EGT readings do not overtake the N2 or N3 readings accordingly.(2 spool or 3 spool engine).
Chances of a Tailpipe fire are minimal if you cut off the fuel quickly enough.
As mentioned before FADEC equipped engines should handle the situation, but as with anything automated you still have to be aware.
JETZ Tech is offline  
Old 4th May 2008, 17:24
  #10 (permalink)  
 
Join Date: Feb 2002
Location: Elysion
Posts: 195
Likes: 0
Received 0 Likes on 0 Posts
Knowing the self-sustaining speed of your engine can be quite useful, although as manufacturers are increasingly reluctant to provide any technical details to aircrew, these numbers might be difficult to come by.

Another thing to consider is that, unless the external power is still plugged in, only battery power will be available, which might lead to a limited number of engine instruments available to monitor the start.

Selecting fuel off will certainly prevent a hot-start, or any start for that matter.
Conan The Barber is offline  
Old 4th May 2008, 18:02
  #11 (permalink)  
Thread Starter
 
Join Date: Jan 2005
Location: W of 30W
Posts: 1,916
Likes: 0
Received 0 Likes on 0 Posts
Thanks for your answers.
Another thing to consider is that, unless the external power is still plugged in, only battery power will be available, which might lead to a limited number of engine instruments available to monitor the start
Excellent point !
Electrical power transfer + System Display logic might, for a few seconds, withdraw from view the critical EGT reading.
CONF iture is offline  
Old 4th May 2008, 18:21
  #12 (permalink)  
 
Join Date: Dec 1998
Location: .
Posts: 2,997
Likes: 0
Received 0 Likes on 0 Posts
Cool

Motoring engine when rpm adequate to blow out the remaining fuel...
If you've lost the APU then there is no air to motor the engine!
spannersatcx is offline  
Old 4th May 2008, 21:43
  #13 (permalink)  
 
Join Date: Feb 2008
Location: Standby...call you back..
Posts: 210
Likes: 0
Received 0 Likes on 0 Posts
Any problem to restart the apu ???
roljoe is offline  
Old 4th May 2008, 23:39
  #14 (permalink)  
 
Join Date: Feb 2007
Location: Down Under
Posts: 124
Likes: 0
Received 0 Likes on 0 Posts
Not in time to continue motoring.
Nepotisim is offline  
Old 5th May 2008, 15:04
  #15 (permalink)  
 
Join Date: Oct 1999
Location: In the oil wealth of sand dunes
Posts: 293
Likes: 0
Received 0 Likes on 0 Posts
Had a similar problem before on the A340-600.
APU was U/S and so we used on ground power units and an air cart.
We start engine 2 first, then engine 1, pushback, set park brake cross bleed start 3 and 4.

This was the plan, however, we instructed the engineer to give air and opened the start master, when the ground power failed completely after the fuel went in. We lose all displays, bells and whistles going off. I continued the start by holding down the ENG key on the ECAM display and continued the starts on battery, and started engine two as well. Not a big deal, but it could go pear shaped quickly.

There are complications in only starting one engine on an A340 (not all busses are supplied) so you have faults ENG1 EPR mode and other ENG 1 minor faults.

The point is, we had a ground power during the start process and managed to continue on battery by holding down a key for the engine page to monitor and it all turned out OK.
planecrazi is offline  
Old 5th May 2008, 15:30
  #16 (permalink)  
 
Join Date: Jan 2005
Location: uk
Posts: 1,266
Likes: 0
Received 0 Likes on 0 Posts
Our Ops Manual for A319/320/321 is supposedly pretty similar to Airbus SOPs from FCOM 3, and includes this line during the engine start bit:

In case the electrical power supply is interrupted during the start sequence (indicated by the loss of ECAM DUs) abort the start by switching OFF the MASTER switch. Then perform a 30-second dry crank.
Doesn't seem to allow for the 'suck-it-and-see' kind of discretion considered on some types during this discussion.
Gary Lager is offline  
Old 5th May 2008, 18:10
  #17 (permalink)  
short flights long nights
 
Join Date: Aug 1999
Posts: 3,884
Received 157 Likes on 50 Posts
I would suggest..cancel the start and have a long slow think. After almost 17000 hours of flying I have always found this works best.
SOPS is offline  
Old 6th May 2008, 03:16
  #18 (permalink)  
 
Join Date: Dec 2004
Location: 4 seasons hotel
Posts: 269
Received 5 Likes on 4 Posts
CONF,

Sounds like you're in the B737. Common to happen as the combination of weak APU,electrical load shed not chopping off the non essentials quick enough and etc. What I used to do was to turn OFF the galley power on pushing back.I am with an Asian carrier that serve hot meal on a 1hr 20min leg.Crew were time pressed to heat meals.

If this senario happen,reach for the STBY PWR tranfer switch to ON,if N2 below 40%,it is unlikely to start.Cut the fuel quickly, if there is a hung start,flame might come out from the front and back of the engine burning up the wing tank and you have no means to motor the engine or blow the flame out.Sitting duck basically. It would be more scary at night since you would only have evac lights in the cabin.
flightleader is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.