737-300 Failed Flap System
Hypothetically speaking,
If your normal Flap system fails at Flap 5 (Hydraulically powered system B), due to a faulty signal from the flap indicator (fails safe to stop asymmetric flap extension), you used the Alternate flap extension system (Electrically driven), and that too failed at flap 10. You are going to land fast, but no great drama.
My question is, if the aforementioned flap indicator was changed by the engineers, and problem rectified, what could have caused the Alternate flap system to fail too? These are supposed to be 2 independent systems are they not?
Any feedback gratefully received.
If your normal Flap system fails at Flap 5 (Hydraulically powered system B), due to a faulty signal from the flap indicator (fails safe to stop asymmetric flap extension), you used the Alternate flap extension system (Electrically driven), and that too failed at flap 10. You are going to land fast, but no great drama.
My question is, if the aforementioned flap indicator was changed by the engineers, and problem rectified, what could have caused the Alternate flap system to fail too? These are supposed to be 2 independent systems are they not?
Any feedback gratefully received.

Joined: Jan 2005
Posts: 303
Likes: 56
From: Europe
You better be very sure that the problem was indeed caused by a faulty flap position indicator before attempting to extend the flaps with the alternate system. If the indicated flap asymmetry was genuine, the alternate flap extension system could easily worsen the situation. The TE Flap Asymmetry checklist warns against using the alternate flaps switch for further extension of the TE flaps for a reason:
CAUTION: Do not attempt to move the trailing edge flaps with the alternate flaps switch as there is no asymmetry protection.
Thread Starter
Joined: Jan 2003
Posts: 131
Likes: 0
From: NW
Indications were normal, ie no asymmetry. When flaps ran to 10, all were symmetric.
Can't understand though how the failure of the normal system resulted in the failure of the Alternate system, or how the replacement of the flap indicator fixed both systems which are supposed to be independant of each other. Maybe I'm missing something here????!!!!!!
Can't understand though how the failure of the normal system resulted in the failure of the Alternate system, or how the replacement of the flap indicator fixed both systems which are supposed to be independant of each other. Maybe I'm missing something here????!!!!!!
Last edited by endofeng; 7th January 2008 at 21:30.
Joined: Apr 2005
Posts: 201
Likes: 0
From: Uk
Yes, the alternate system should work if it was an indicator asymmetry fault.
As for the alternate system failing, it could well be the air loading on the flaps combined with the alternate drive motor being old, as I can only assume that after the indicator replacement both systems tested fine and a detailed inspection was carried out of the flaps for damage or FOD etc.
If it turns out that it was definetly an indicator problem giving false asymmetry signals after its overhaul/repair I would urge your engineering department to replace the alternate drive motor as a precaution.
As for the alternate system failing, it could well be the air loading on the flaps combined with the alternate drive motor being old, as I can only assume that after the indicator replacement both systems tested fine and a detailed inspection was carried out of the flaps for damage or FOD etc.
If it turns out that it was definetly an indicator problem giving false asymmetry signals after its overhaul/repair I would urge your engineering department to replace the alternate drive motor as a precaution.

Joined: Jan 2005
Posts: 303
Likes: 56
From: Europe
I agree with ASFKAP. Just to clarify my earlier answer:
That fail safe protection is activated when a needle split is sensed by the indicator. If there was no indicated asymmetry (i.e.: no noticeable needle split) then the flap position indicator most likely has nothing to do with it. Especially knowing that the alternate flap extension system didn't work either.
Originally Posted by endofeng
due to a faulty signal from the flap indicator (fails safe to stop asymmetric flap extension)
Last edited by xetroV; 8th January 2008 at 12:16.
Thread Starter
Joined: Jan 2003
Posts: 131
Likes: 0
From: NW
The engineers changed the flap position indicator and this apparently has cured both the normal and alternate flap problem. I'm not convinced though, as they are two independant systems - hence my thread.
Tech entry penned off as replacement of flap position indicator, which has fixed normal system, and alternate system. Have flown the a/c since, and normal system fine, but how do I know that alternate system hasn't still got a fault (without running alternate flap drill) ?.....
As said above, it could be that both systems tested after replacement of flap position indicator on the ground were found to be satisfactory, but alternate under air loads may fail again = problems for next crew (hopefully not me) having to use alternate system!
Thanks for the input guys, given me a an insight into problems which may have caused the alternate system to fail too. Bad day when both your systems fail, but after all, they are machines, and all machines break
Tech entry penned off as replacement of flap position indicator, which has fixed normal system, and alternate system. Have flown the a/c since, and normal system fine, but how do I know that alternate system hasn't still got a fault (without running alternate flap drill) ?.....
As said above, it could be that both systems tested after replacement of flap position indicator on the ground were found to be satisfactory, but alternate under air loads may fail again = problems for next crew (hopefully not me) having to use alternate system!
Thanks for the input guys, given me a an insight into problems which may have caused the alternate system to fail too. Bad day when both your systems fail, but after all, they are machines, and all machines break
Joined: Sep 2007
Posts: 946
Likes: 0
From: Up left - Down right
There would be no problem if you were to enter a log item referring to the said indicator change and ask for further investigation.
Who cares if the engineer looses face, better him than you!
Who cares if the engineer looses face, better him than you!




, our lives are in your hands.